SICK TR4 Safety Interlock Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

₩462,440.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2027년 1월 15일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩462,440.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9064
제조사 부품 번호:
TR4-SEM01CB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

Yes

Safety Contacts

2

Housing Material

Valox

Series

TR4

Contact DC Voltage

24V dc

Contact AC Voltage

230V ac

Switch Contact Current

200mA

IP Rating

IP67, IP69K

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

IEC 60529

Length

88mm

Number of Head Directions

5

Width

25mm

Depth

20mm

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, 24V DC Supply Voltage, IP67 - TR4-SEM01CB


This safety interlock switch is a non-contact RFID device designed to monitor access points in automated environments. It provides two safety outputs with self-monitoring semiconductor OSSD signals and is suited to series wiring with diagnostic options. The unit operates from a 24V DC supply and connects via a 0.2m cable with an M12, 8-pin plug

longer runs up to 200m are supported. The housing is MADE from Valox and the enclosure is rated for both IP67 and IP69K protection, allowing use in harsh and hygienic conditions.

Features and Benefits:


• SIL3 safety integrity for high-risk applications
• Category 4 performance level PL e compliance
• Self-monitoring outputs limit hazardous-state duration
• 200mA output current supports Compact control loads
• Operating range -25°C to +70°C for diverse climates

Applications


• Suitable for safety guarding on conveyor systems
• Ideal for food-sector washdown areas requiring IP69K
• Used with safe evaluation units in series connections
• Can be used for access control on machinery guards
• Suitable for installations needing multi-direction actuation

How is the device connected to a control system?


It uses an M12, 8-pin cable with flying leads and supports long connecting cables up to 200m.

What is the device’s behaviour when a fault is detected?


At least one semiconductor safety output switches to the OFF state to maintain a safe condition.

Which electrical characteristics govern its outputs?


Outputs are self-monitoring OSSDs with ≤200mA output current and supply range 20.4V DC to 26.4V DC.

What mechanical stresses can it tolerate?


It withstands vibration at 10Hz to 55Hz with 3.5mm amplitude and shock up to 30g, 11 ms.

Are multiple sensors chainable and is diagnostic data available?


Sensors can be linked in series with Flexi Loop for diagnostics or with a T-connector without diagnostics.