SICK MLP1 Safety Interlock Switch, Power Actuator Included, Valox

Subtotal (1 unit)*

₩856,220.00

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 추가로 2026년 11월 04일 부터 4 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩856,220.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-8871
제조사 부품 번호:
MLP1-SMMF0AC
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

Power

Product Type

Safety Interlock Switch

Actuator Included

Yes

Housing Material

Valox

Series

MLP1

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-20°C

IP Rating

IP67

Switch Contact Current

100mA

Maximum Operating Temperature

55°C

Hazardous Area Certification

No

Width

60mm

Length

120mm

Depth

38.5mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
MY

SICK MLP1 Series Safety Interlock Switch, 120mm Length, Valox Housing - MLP1-SMMF0AC


This safety interlock switch is designed to monitor access points and prevent hazardous machinery operation when guards are open. It uses RFID sensing with a power-to-lock mechanism and provides self-monitoring semiconductor outputs for safety circuits. The unit operates from 24V DC supply and includes an actuator. It is suited to industrial environments where a sealed, Compact interlock is required.

Features and Benefits:


• SIL 3 safety integrity level for high-risk applications
• Category 4, PL e performance for Advanced safety control
• Power-to-lock mechanism providing 500N to 550N locking force
• IP67 sealed enclosure to protect against dust and water
• OSSD outputs limited to 100mA for safe integration

Applications


• Suitable for guarding on automated production lines
• Ideal for cascade connections with diagnostic capability
• Used with safe evaluation units in series connections
• Can be used for process protection where access control is required

What supply voltages does it require?


The sensor and magnet operate from 24V DC with specified tolerance ranges for individual and cascade use.

How are diagnostics and series connections handled?


It supports connection via T-connector without diagnostics or Flexi Loop for diagnostic-capable cascades and uses M12 cabling.

What environmental limits apply to operation?


It functions between -20°C and +55°C and withstands vibration and shock ratings per the specified standards.

What are the signalling and timing behaviours?


The device provides self-monitoring OSSD outputs, a response time of 50 MS, release time of 100 MS and a switch-on time of 2.5 s.

관련된 링크들