SICK TR4 Safety Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

₩551,720.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 18일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩551,720.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-4392
제조사 부품 번호:
TR4-SDU02CB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

RFID

Product Type

Safety Switch

Actuator Included

Yes

Safety Contacts

2 NO

Housing Material

Valox

Series

TR4

Contact AC Voltage

230V ac

Minimum Operating Temperature

-25°C

Switch Contact Current

200mA

IP Rating

IP67, IP69K

Contact DC Voltage

24V dc

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

IEC 60529

Width

25mm

Depth

20mm

Number of Head Directions

5

Length

88mm

COO (Country of Origin):
DO

SICK TR4 Series Safety Switch, IP67, 24V Supply Voltage - TR4-SDU02CB


This safety switch is a non-contact RFID interlock designed to protect access points and guard doors in industrial automation. It provides two safety outputs with self-monitoring semiconductor technology and is intended for integration with safety controllers and Flexi Loop diagnostics. The unit operates from a 24V supply and is suited to harsh environments thanks to robust sealing and a Compact form.

Features and Benefits:


• RFID sensing ensures non-contact operation and reduced wear
• 2 safe outputs deliver safety-related signalling with self-monitoring
• Performance level PL e and SIL 3 enable use in high-risk applications
• IP69K ingress protection permits pressurised washdown environments
• Cable with M12 plug supports simple direct connection

Applications


• Suitable for machine guard door monitoring on production lines
• Used with safety controllers employing Flexi Loop diagnostics
• Ideal for food-industry equipment requiring washdown resistance
• Can be used for safeguarding access in robotics cells

What are the temperature operating limits?


It functions across an ambient range of -25°C to +70°C.

How is the switch connected electrically?


It uses a 0.2m cable with a 5-pin M12 plug and supports cables up to 200m.

What safety classifications does it meet?


It is rated Category 4 under EN ISO 13849 and SIL 3 per IEC 61508.

What mechanical stresses can it tolerate?


The device withstands vibration at 10Hz to 55Hz with 3.5mm amplitude and shock up to 30g, 11 ms.