SICK TR4 Safety Interlock Switch, RFID Actuator Included, Vistal
- RS 제품 번호:
- 285-9057
- 제조사 부품 번호:
- TR4-SAU01CB
- 제조업체:
- SICK
Subtotal (1 unit)*
₩476,200.00
재고있음
- 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩476,200.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 285-9057
- 제조사 부품 번호:
- TR4-SAU01CB
- 제조업체:
- SICK
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | SICK | |
| Product Type | Safety Interlock Switch | |
| Lock Style | RFID | |
| Actuator Included | Yes | |
| Safety Contacts | 2 | |
| Housing Material | Vistal | |
| Series | TR4 | |
| IP Rating | IP67, IP69K | |
| Switch Contact Current | 200mA | |
| Minimum Operating Temperature | -25°C | |
| Contact AC Voltage | 230V ac | |
| Contact DC Voltage | 24V dc | |
| Maximum Operating Temperature | 70°C | |
| Hazardous Area Certification | No | |
| Length | 67.1mm | |
| Number of Head Directions | 5 | |
| Width | 67.1mm | |
| Standards/Approvals | IEC 60529 | |
| 모두 선택 | ||
|---|---|---|
브랜드 SICK | ||
Product Type Safety Interlock Switch | ||
Lock Style RFID | ||
Actuator Included Yes | ||
Safety Contacts 2 | ||
Housing Material Vistal | ||
Series TR4 | ||
IP Rating IP67, IP69K | ||
Switch Contact Current 200mA | ||
Minimum Operating Temperature -25°C | ||
Contact AC Voltage 230V ac | ||
Contact DC Voltage 24V dc | ||
Maximum Operating Temperature 70°C | ||
Hazardous Area Certification No | ||
Length 67.1mm | ||
Number of Head Directions 5 | ||
Width 67.1mm | ||
Standards/Approvals IEC 60529 | ||
- COO (Country of Origin):
- DO
SICK TR4 Series Safety Interlock Switch, IP67, Vistal Housing - TR4-SAU01CB
This safety interlock switch is a non-contact RFID device designed to monitor access to guarded machinery. It provides dual safe outputs with self-monitoring semiconductor circuitry and is intended for integration into safety systems requiring high integrity and diagnostic options. The unit is suitable for use where contamination or washdown are present and operates across a wide ambient temperature range.
Features and Benefits:
• SIL3 safety integrity enhances functional safety performance
• Category 4 design ensures highest risk-reduction level
• Two OSSD outputs provide monitored switching capability
• Encapsulated electronics deliver IP67 and IP69K ingress protection
• Self-monitoring outputs limit output current to 200mA
• Category 4 design ensures highest risk-reduction level
• Two OSSD outputs provide monitored switching capability
• Encapsulated electronics deliver IP67 and IP69K ingress protection
• Self-monitoring outputs limit output current to 200mA
Applications
• Suitable for washdown production lines in food environments
• Ideal for linking multiple guards with Flexi Loop diagnostics
• Used with safe evaluation units in machine safety circuits
• Can be used for non-hazardous area interlocks in factories
• Suitable for conveyor and packaging guard monitoring
• Ideal for linking multiple guards with Flexi Loop diagnostics
• Used with safe evaluation units in machine safety circuits
• Can be used for non-hazardous area interlocks in factories
• Suitable for conveyor and packaging guard monitoring
What supply voltage does it require?
It is powered from 24V DC within a 20.4V DC to 26.4V DC range.
How are connections MADE to a control system?
It uses an 8-pin M12 cable plug with a 0.2m pigtail and supports long cables up to 200m.
What mechanical stresses can it withstand?
The device resists vibration from 10Hz to 55Hz at 3.5mm and shock up to 30g for 11 ms.
How quickly does it respond to a safety event?
Nominal response time is 45 MS with a release time of 360 MS and switch-on time of 2 s.
What diagnostic or series-connection options exist?
It supports series connection with Flexi Loop for diagnostics and T-connector use without diagnostics.
관련된 링크들
- SICK TR4 Safety Switch, RFID Actuator Included, Valox
- SICK TR4 Safety Interlock Switch, RFID, Vistal
- SICK TR4 Safety Interlock Switch, RFID Actuator Included, Valox
- SICK STR1 Safety Interlock Switch, RFID Actuator Included, Vistal
- SICK Type 4 (En Iso 14119), EN ISO 14119, Category 4 (EN ISO 13849) TR4 Safety Switch, RFID Actuator Included, Valox
- SICK STR1 Safety Switch, RFID Actuator Included, Vistal
- SICK STR1 Safety Switch, RFID Actuator Included, Vistal, Electronic
- SICK STR1 Safety Interlock Switch, RFID, Vistal