SICK TR4 Safety Interlock Switch, RFID, Vistal

Subtotal (1 unit)*

₩483,040.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 17일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩483,040.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9063
제조사 부품 번호:
TR4-SDM10PB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2

Housing Material

Vistal

Series

TR4

Switch Contact Current

200mA

IP Rating

IP69K, IP67

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Contact AC Voltage

230V ac

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Standards/Approvals

IEC 60529

Width

25mm

Depth

20mm

Number of Head Directions

5

Length

88mm

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, 24V DC Supply, IP67 - TR4-SDM10PB


This safety interlock switch is a non-contact RFID device designed to monitor access points and protect personnel in industrial settings. It operates from a 24V DC supply and provides two safely monitored semiconductor outputs for integration into safety circuits. The unit is suited to control-cabinet wiring with diagnostic capability and is built to withstand harsh environments and routine industrial stresses.

Features and Benefits:


• SIL 3 safety level delivering high-integrity protection
• Category 4 safety enabling Advanced risk reduction
• PFHD 6.03e-10 offering quantifiable failure metrics
• 10m cable with long-run capability to 200m reducing wiring changes
• Self-monitoring OSSD outputs limiting external fault propagation

Applications


• Suitable for machine-guard monitoring in manufacturing lines
• Ideal for food-industry washdown environments requiring IP69K
• Used with safety controllers needing PL e performance
• Can be used for access control on automated cells
• Suitable for installations requiring vibration and shock resilience

What temperatures can it operate within?


It functions across an ambient range of -25°C to +70°C.

How are status indications provided on the device?


Built-in LEDs provide Visual status and diagnostic indication.

What electrical loads can the outputs drive?


Each semiconductor output supplies up to 200mA and accepts 24V DC control voltage.

How is the unit connected and what cable characteristics apply?


It uses a 10m PVC-sheathed cable, 6.5mm diameter, 0.25mm² conductors with specified bend radii.