SICK TR4 Safety Interlock Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

₩380,020.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 3 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩380,020.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9058
제조사 부품 번호:
TR4-SBM01CB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

RFID

Product Type

Safety Interlock Switch

Actuator Included

Yes

Safety Contacts

2

Housing Material

Valox

Series

TR4

IP Rating

IP67, IP69K

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Switch Contact Current

200mA

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Length

67.1mm

Width

67.1mm

Standards/Approvals

IEC 60529

Number of Head Directions

5

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, IP67, Valox housing - TR4-SBM01CB


This safety interlock switch is a non-contact RFID device designed to monitor access points in industrial machinery and guarded areas. It provides two safety outputs with self-monitoring semiconductor technology and is intended for integration with safety evaluation units. The unit operates from a 24V DC supply and includes an actuator, offering multi-directional actuation for demanding production environments.

Features and Benefits:


• SIL 3 safety level increases functional safety assurance
• PL e Category 4 achieves high performance in control systeMS
• IP67 IP69K protection ensures dustproof, waterproof operation
• Self-monitoring outputs limit dangerous output current to 200mA
• 360 MS release time supports controlled safety restart behaviour

Applications


• Suitable for safeguarded machinery access monitoring
• Ideal for conveyors requiring non-contact interlock switching
• Used with safety controllers in series connection architectures
• Can be used for hygienic washdown environments requiring IP69K
• Used for installations needing multi-directional actuation flexibility

What supply voltage range does it accept?


It runs from 20.4V DC to 26.4V DC and consumes ≤50mA typical.

How does the device signal safe/unsafe outputs?


Two self-monitoring semiconductor outputs (OSSDs) provide safety signals with internal diagnostics.

What environmental temperatures can it tolerate?


It operates between -25°C and +70°C for standard industrial conditions.

How is it connected to safety evaluation equipment?


It uses an M12 8-pin connection with a 0.2m cable and supports long cable runs up to 200m.

What mechanical robustness does it offer against vibration and shock?


It withstands 10Hz to 55Hz vibration at 3.5mm and shock up to 30g for 11 ms.