SICK TR4 Safety Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

₩551,720.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 21일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩551,720.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-4393
제조사 부품 번호:
TR4-SDU03PB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Switch

Lock Style

RFID

Actuator Included

Yes

Housing Material

Valox

Series

TR4

IP Rating

IP67, IP69K

Switch Contact Current

200mA

Contact AC Voltage

230V ac

Contact DC Voltage

24V dc

Minimum Operating Temperature

-25°C

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Standards/Approvals

IEC 60529

Width

25mm

Length

88mm

Depth

20mm

Number of Head Directions

5

COO (Country of Origin):
DO

SICK TR4 Series Safety Switch, IP67, Valox Housing - TR4-SDU03PB


This safety switch is a non-contact RFID interlock designed for safeguarding access points in industrial automation. It provides two monitored semiconductor safety outputs suitable for series connection within a control cabinet and operates from a 24V DC supply. The device is built for continuous industrial use with LED status indication and a 3M PVC cable for straightforward wiring.

Features and Benefits:


• SIL3 safety integrity enabling high-risk application use
• PL e category 4 delivering Advanced fault tolerance
• 200mA output current supporting low-power safety devices
• IP69K protection allowing high-pressure washdown capability
• -25 to 70°C rating preserving operation across temperature ranges

Applications


• Suitable for food-processing machinery with washdown regimes
• Ideal for automated assembly line guard monitoring
• Used for safety fencing where Compact interlocks are required
• Can be used for robotics cell door monitoring with diagnostics
• Suitable for control-cabinet series connection with diagnostics

What type of outputs does it provide?


It provides two self-monitoring semiconductor outputs (OSSDs) with automatic fault detection.

How does the actuator Interface with the sensor?


The system uses an included RFID actuator that pairs to the uniquely coded sensor surfaces for non-contact switching.

What cable details are relevant for installation?


The device has a 3M PVC-sheathed cable, 6.5mm diameter, 0.25mm² conductors and supports extension up to 200m.

How does it behave when a fault is detected?


Upon a fault at least one safety-related semiconductor output switches to the OFF state to maintain a safe condition.

How long is the expected mission time for safety calculations?


The device uses a TM of 20 years for performance assessments in accordance with applicable standards.