SICK TR4 Safety Switch, RFID Actuator Included, Valox

Subtotal (1 unit)*

₩345,680.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 24일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩345,680.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-4380
제조사 부품 번호:
TR4-SAM03PB
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Lock Style

RFID

Product Type

Safety Switch

Actuator Included

Yes

Safety Contacts

2

Housing Material

Valox

Series

TR4

IP Rating

IP69K, IP67

Minimum Operating Temperature

-25°C

Contact AC Voltage

230V ac

Switch Contact Current

200mA

Contact DC Voltage

24V dc

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Length

67.1mm

Number of Head Directions

5

Width

19.8mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
DO

SICK TR4 Series Safety Switch, 24V DC Supply Voltage, Valox Housing - TR4-SAM03PB


This safety switch is a non-contact RFID interlock designed for machine-safety applications where monitored access and diagnostics are required. It provides dual safe outputs with self-monitoring semiconductor signalling for integration in control-cabinet safety circuits. The device operates from a 24V DC supply and includes a 3M cable for connection, offering LED status indication and a Compact cylindrical form suited to confined installations.

Features and Benefits:


• SIL 3 safety level delivering high functional safety performance
• Category 4 classification enabling Advanced safety architectures
• Two self-monitoring outputs providing separated safety signalling
• IP69K / IP67 rating permitting wash-down and high-pressure cleaning
• Temperature resilient -25°C to 70°C supporting harsh environments

Applications


• Suitable for industrial RFID interlock switch installations on guards
• Ideal for food-industry areas requiring IP69K hygiene cleaning
• Used with control-cabinet safety logic for series monitoring
• Can be used for access monitoring on automated production lines
• Suitable for integration where a Compact safety-switch form factor is needed

How are external faults detected and handled?


External faults such as short-circuit or cross-circuit are detected within the device

detection time is specified as up to 100 MS and the safe state drives at least one semiconductor output to OFF.

What supply and output electrical limits apply?


Supply voltage is 24V DC with an operating range of 20.4V DC to 26.4V DC and each output can source up to 200mA.

What mechanical durability can I expect for switching cycles?


The electrical life is rated at 10x10^6 switching cycles under specified conditions.

How is the device connected and what cable options exist?


It ships with a 3M PVC-sheathed cable with 0.25mm² conductors and permits fixed installations up to 200m total cable length.