SICK TR10 Safety Switch, Power, ABS, Electronic

Subtotal (1 unit)*

₩1,163,000.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 10월 26일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩1,163,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-4358
제조사 부품 번호:
TR10-SLM03P
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Switch

Lock Style

Power

Lock Type

Electronic

Actuator Included

No

Housing Material

ABS

Series

TR10

IP Rating

IP67, IP69K, IP66

Switch Contact Current

200mA

Minimum Operating Temperature

0°C

Contact DC Voltage

24V dc

Contact AC Voltage

230V ac

Maximum Operating Temperature

55°C

Hazardous Area Certification

No

Number of Head Directions

4

Standards/Approvals

CE

Width

50mm

Length

140mm

Depth

33mm

COO (Country of Origin):
DO

Overview


The TR10 Lock safety locking device combines the best features of tried and tested technology: outstanding manipulation-proofing for the RFID technology that monitors the actuator, plus a high-strength, highly reliable mechanical locking mechanism. The sensor’s self-monitoring semiconductor outputs (OSSDs) can be cascaded and, thanks to a PL e performance level (EN ISO 13849), ensure maximum safety – for both door monitoring and locking monitoring.

Two codings are available, affording applications more flexibility. The universally coded sensors accept all suitable actuators, while uniquely coded sensors only allow actuators that have previously been taught in. The bistable solenoid coil consumes only a small amount of power and produces no heat when the system is either locked or unlocked.

At a glance


PL e for door and locking monitoring (EN ISO 13849)

1,690 N locking force

RFID actuator with low or high coding level (EN ISO 14119)

Enclosure rating IP 67, IP 69K

Power to lock or power to release variants

Reliable series connection of safety outputs (OSSDs)

Four actuation directions

Flexi-Loop-ready

Your Benefit


The high coding level of the actuator meets all the EN ISO 14119 requirements relating to manipulation-proofing without additional measures

Self-monitoring semiconductor outputs (OSSDs) afford a high level of safety

Reliable series connection reduces installation work

Rugged IP 69K housing ideally suited to use in heavily contaminated environments

Slim housing design with flexible actuator installation options enables simple machine integration

Bistable solenoid coil consumes only a small amount of power and produces no heat when the system is either locked or unlocked

Fast diagnosis via LED status indicator

Applications


Fields of applications

Protection of persons in the event of the machine making dangerous overrun movements

Process protection for automated production systems

Applications requiring a high standard of hygiene

Applications requiring a high level of manipu