SICK STR1 Safety Switch, RFID Actuator Included, Vistal, Electronic

Subtotal (1 unit)*

₩476,200.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 11월 27일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩476,200.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-4299
제조사 부품 번호:
STR1-SASU10P5
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Switch

Lock Style

RFID

Lock Type

Electronic

Actuator Included

Yes

Safety Contacts

1

Housing Material

Vistal

Series

STR1

Contact DC Voltage

24V dc

Minimum Operating Temperature

-30°C

IP Rating

IP69K, IP67

Switch Contact Current

100mA

Contact AC Voltage

230V ac

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Width

40mm

Standards/Approvals

IEC 60529

Length

18mm

Number of Head Directions

5

Depth

26mm

COO (Country of Origin):
MY

SICK STR1 Series Safety Switch, 24V DC Supply Voltage, IP69K - STR1-SASU10P5


This safety switch is a non-contact RFID sensor and actuator system designed to monitor protective guards and access points in industrial settings. It provides safety outputs and diagnostics for individual wiring applications, operates from a 24V DC supply and is housed in a robust VISTAL® enclosure to suit harsh environments.

Features and Benefits:


• SIL3 safety integrity delivers high-risk functional protection
• Two safe outputs enable redundant safety signalling
• Output current limited to 100mA for controlled switching
• Operating range accommodates temperatures up to 70°C
• IP69K and IP67 rating resists washdown and dust ingress

Applications


• Suitable for food-industry washdown environments requiring IP69K
• Used with guarded machines needing redundant safety outputs
• Ideal for assembly lines requiring non-contact interlocks
• Can be used where compact, high-temperature sensors are needed
• Suitable for systems needing cable connection with diagnostics

What connection options are provided for integration?


It uses a 5-wire cable with a 10m factory-fitted lead and allows long connecting cables up to 200m.

How is actuator alignment and direction handled?


The device supports five actuation directions and three Active sensor surfaces on TOP and both sides for versatile alignment.

What safety categories and performance levels does it meet?


It is specified to Category 4 and Performance Level PLe with a PFHD of 5.1x10-9 and a 20-year mission time.

How are faults and status indicated?


Built-in LEDs provide status display and diagnostics for detection of internal or external faults.

What are the electrical timing characteristics relevant to system design?


Response time is 40 MS, release time on approach is 100 MS, risk detection time is 80 MS and switch-on time is 2.5 s.

관련된 링크들