RS 제품 번호:
285-9014
제조사 부품 번호:
STR1-SAFM10P5
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Interlock Switch

Actuator Included

Yes

Safety Contacts

2

Housing Material

Vistal

Series

STR1

IP Rating

IP69K, IP67

Switch Contact Current

100mA

Contact AC Voltage

230V ac

Number of Auxiliary Contacts

1

Contact DC Voltage

24V dc

Minimum Operating Temperature

-30°C

Hazardous Area Certification

No

Maximum Operating Temperature

70°C

Length

18mm

Standards/Approvals

CE

Width

40mm

Depth

26mm

Number of Head Directions

5

COO (Country of Origin):
MY

SICK STR1 Series Safety Interlock Switch, IP69K, VISTAL Housing - STR1-SAFM10P5


This safety interlock switch is a non-contact RFID sensor and actuator system designed to monitor access points in industrial automation. It delivers safety outputs via self-monitoring semiconductor outputs and an auxiliary contact while operating from a 24V DC supply. The unit is intended for harsh environments with high ingress protection and works across a wide ambient temperature range for continuous machine-safety applications.

Features and Benefits:


• SIL3 safety integrity for high-demand safety applications
• Category 4 performance level PL e for functional safety compliance
• Dual safe outputs provide redundant fault-tolerant switching
• 10m cable length enabling flexible installation distances
• IP69K-rated enclosure resists high-pressure washdown

Applications


• Suitable for guarding on automated assembly lines
• Ideal for washdown areas in food-processing plants
• Used with safety Gates on robotic workcells
• Can be used for perimeter access monitoring in manufacturing
• Suitable for machine-tool enclosures requiring Compact switches

What supply voltage range does it accept?


It operates from a 24V DC supply within a 19.2V DC to 28.8V DC window.

How are the outputs configured for safety circuitry?


It provides two self-monitoring semiconductor outputs that are supervised and an auxiliary contact with complementary switching.

What environmental stresses can it tolerate?


The device meets IP67 and IP69K protection and withstands vibration 10Hz to 55Hz, 1mm and shock 30g, 11 ms.

How long is the cable and what is its construction?


It has a 10m PVC-sheathed cable with copper conductors and 0.12mm² cross-section.

What response timing should be expected for safety reactions?


Typical response time is 40 MS, release time 100 MS, and an 80 MS fault-detection interval.