Pico Technology Oscilloscope Probe, Differential Type, 25 MHz, 20:1, 200:1, BNC Connector

Subtotal (1 unit)*

₩818,540.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 39 개 단위 배송 준비 완료
  • 추가로 2026년 12월 02일 부터 2 개 단위 배송
  • 추가로 2026년 12월 09일 부터 1 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩818,540.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
898-6766
Distrelec 제품 번호:
300-15-497
제조사 부품 번호:
TA057
제조업체:
Pico Technology
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pico Technology

Probe Type

Differential

Product Type

Oscilloscope Probe

Attenuation

20:1, 200:1

Bandwidth

25MHz

Maximum Common Mode Input Voltage

1kV

Connector Type

BNC

Number of Probes

2

Safety Category Level

CAT III

Safety Category Voltage

1kV

Rise Time

14ns

COO (Country of Origin):
TW

Pico Technology Oscilloscope Probe, 25MHz Bandwidth, Differential Probe - TA057


This oscilloscope probe is a differential measurement accessory designed for industrial and laboratory use. It provides isolated signal acquisition for systems where measuring across two points without a common reference is required, and connects to instruments via a BNC interface. The probe set supports higher-voltage environments and is intended for tasks where safety-rated input handling is necessary.

Features and Benefits:


• 25MHz bandwidth enables stable low-frequency waveform capture
• 14ns rise time supports transient edge detection
• 20:1 and 200:1 attenuation options extend input range
• CAT III safety classification permits use on building installations
• 1kV common-mode tolerance allows measurement across high potentials

Applications


• Suitable for measuring differential signals in power electronics
• Ideal for field testing on industrial distribution panels
• Used with benchtop oscilloscopes requiring isolated inputs
• Can be used for maintenance on control system cabling
• Used for troubleshooting equipment with high common-mode voltages

How many probes are included in the package?


The set contains two individual probes for simultaneous dual-channel measurement.

What connector type is used to Interface with instruments?


Each probe terminates in a BNC connector for standard oscilloscope inputs.

What attenuation settings are available and why do they matter?


Users can select 20:1 or 200:1 attenuation to match signal amplitude to the instrument input range.

What safety rating does the probe meet for on-site electrical work?


It is rated to CAT III for use on fixed installation points within buildings.

What maximum common-mode voltage can it withstand during measurement?


The probes tolerate up to 1kV common-mode voltage for differential measurements.