Pico Technology TA041 Oscilloscope Probe, Differential Type, 25 MHz, 10:1, 100, 1, BNC Connector

Subtotal (1 unit)*

₩805,840.00

Add to Basket
수량 선택 또는 입력
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
수량
한팩당
1 +₩805,840.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
898-6744
Distrelec 제품 번호:
300-15-496
제조사 부품 번호:
TA041
제조업체:
Pico Technology
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pico Technology

Probe Type

Differential

Product Type

Oscilloscope Probe

Attenuation

10:1, 100, 1

Bandwidth

25MHz

Maximum Common Mode Input Voltage

700V

Connector Type

BNC

Model Number

TA041

Number of Probes

2

Safety Category Level

CAT III

Safety Category Voltage

700V

Rise Time

14ns

COO (Country of Origin):
TW

Pico Technology Oscilloscope Probe, 25MHz Bandwidth, Differential Probe - TA041


This oscilloscope probe is designed to measure differential signals in power and control systems where isolation from earth is necessary. It connects via a BNC Interface and is supplied as a pair, enabling simultaneous dual-channel measurements. The probe supports varied attenuation settings to match different signal amplitudes and is intended for use in moderate bandwidth diagnostic work and power-electronics testing.

Features and Benefits:


• 25MHz bandwidth delivers clear reproduction of low-frequency transients
• 14ns rise time captures moderate-speed edge transitions
• 10:1, 100:1, 1:1 attenuation adapts to diverse signal levels
• 700V common-mode input handles elevated differential voltages
• CAT III 1000V safety rating permits use on building electrical systems

Applications


• Suitable for debugging power-electronics converters and inverters
• Used with benchtop oscilloscopes for dual-channel differential measurements
• Ideal for fault tracing on control circuits with elevated common-mode voltages
• Can be used for educational labs requiring safe high-voltage probing
• Used for comparative waveform analysis between isolated nodes

How many probes are supplied in the package?


Two probes are included to facilitate simultaneous differential or dual-channel work.

What connector type is used to Interface with an oscilloscope?


A BNC connector is provided for each probe to ensure standard scope connection.

Which signal attenuation options are available and why use them?


The probe offers 10:1, 100:1 and 1:1 attenuation to accommodate a range of input amplitudes while maintaining instrument input limits.

What is the maximum common-mode voltage the probe can tolerate?


It can withstand up to 700V of common-mode input voltage for measurements with significant differential offsets.

관련된 링크들