Pico Technology TA044 Oscilloscope Probe, Differential Type, 70 MHz, 100:1, 1000:1, BNC Connector

Subtotal (1 unit)*

₩2,060,660.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 64 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,060,660.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
898-6750
제조사 부품 번호:
TA044
제조업체:
Pico Technology
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pico Technology

Product Type

Oscilloscope Probe

Probe Type

Differential

Attenuation

100:1, 1000:1

Bandwidth

70MHz

Maximum Common Mode Input Voltage

7kV

Connector Type

BNC

Model Number

TA044

Number of Probes

2

COO (Country of Origin):
TW

Pico Technology Oscilloscope Probe, 70MHz Bandwidth, Differential Probe - TA044


This oscilloscope probe is a differential test accessory designed to measure voltage differences between two points in circuits where single-ended probes are unsuitable. It connects via BNC and is supplied as a two-probe set to support dual-channel measurements. The device is intended for use where high common-mode voltages occur and where selectable signal scaling is required.

Features and Benefits:


• 70 MHz bandwidth for capturing mid-frequency signal content
• Differential configuration for measuring voltage differences directly
• 100:1 and 1000:1 attenuation options for flexible signal scaling
• 7,000 V common-mode input capacity for high-voltage environments
• BNC connector offers secure instrument Interface

Applications


• Suitable for measuring differential signals on power stages
• Ideal for dual-channel comparative waveform analysis
• Used with oscilloscopes requiring high-voltage input handling
• Can be used for safe probing of transformer secondary circuits
• Useful for validation of isolation barriers in test setups

How many probes are included in the set?


The supply contains two individual probes configured for differential use.

What connector type is required on the oscilloscope?


The Interface uses BNC connectors and requires corresponding BNC inputs on the instrument.

What attenuation settings are available and when should I use them?


Two attenuation ratios are provided: 100:1 for moderate voltages and 1000:1 for much higher signal amplitudes to keep the input within the instrument’s range.

What level of common-mode voltage can be tolerated?


The probe is rated to handle common-mode voltages up to 7,000 V, enabling measurements in high-voltage systems.

Note

The spring hooks supplied with this probe are rated at 1000 V.