사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | GEORGIN | |
| Number of Channels | 2 | |
| Product Type | Intrinsic Security Power Supply | |
| Barrier Type | Galvanic Barrier | |
| Mount Type | DIN Rail | |
| Hazardous Area Certification | ATEX | |
| Safety Current Resistance | 50Ω | |
| Terminal Type | Plug-In Cage Clamp | |
| IP Rating | IP54 | |
| Maximum Safety Voltage | 27.5V | |
| Signal Type | 4 to 20 mA | |
| Minimum Operating Temperature | -20°C | |
| Maximum Safety Current | 80.1mA | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | EN/CEI 61010-1, EN/CEI 60079-11 (Ex ia) I or (Ex ia) IIC or (Ex ia) IIB (Ex iaD) I or (Ex iaD) IIC or (Ex iaD) IIB, EN/CEI 60079-0, EN/CEI 61326 & CEI 61000-6-2 | |
| Series | BX | |
| 모두 선택 | ||
|---|---|---|
브랜드 GEORGIN | ||
Number of Channels 2 | ||
Product Type Intrinsic Security Power Supply | ||
Barrier Type Galvanic Barrier | ||
Mount Type DIN Rail | ||
Hazardous Area Certification ATEX | ||
Safety Current Resistance 50Ω | ||
Terminal Type Plug-In Cage Clamp | ||
IP Rating IP54 | ||
Maximum Safety Voltage 27.5V | ||
Signal Type 4 to 20 mA | ||
Minimum Operating Temperature -20°C | ||
Maximum Safety Current 80.1mA | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals EN/CEI 61010-1, EN/CEI 60079-11 (Ex ia) I or (Ex ia) IIC or (Ex ia) IIB (Ex iaD) I or (Ex iaD) IIC or (Ex iaD) IIB, EN/CEI 60079-0, EN/CEI 61326 & CEI 61000-6-2 | ||
Series BX | ||
The galvanically insulated interface is an associated intrinsic safety item of equipment that is installed in a safe zone or in zone 2 in an IP 54 housing, thanks to the Ex nA protection mode. Its mission is to limit the level of energy that may appear in an electric circuit routed through a potentially explosive area, whatever the connection established upstream.
In addition to its energy-limiting function, its facilitates the use of signals in safe areas (e.g., relays), converts signals (e.g., 4/20 mA to 0-10V) or duplicates signals. Other functions are also available, such as the threshold relay or powering intrinsic safety.
Transmitter power supply
Input: 1 x 4/20mA
Output: 1 x 4/20mA
Option: without, clamp terminals
Power supply: 24/48 Vdc
DIN rail mounting housing
ATEX / IECEx informations:
EC type examination certificate LCIE 02 ATEX 6104X
IECEx LCI 09.0013X certificate
[Ex ia] IIC (-20 °C < Ta < 60 °C)
Group II (surface) - category (1) G/D
Installation in safe zone
Barrier for equipment installed in zone 0,1,2 et 20,21,22
See leaflet for a safe use
관련된 링크들
- GEORGIN 1 Channel Intrinsic Security Power Supply, ATEX
- GEORGIN 2 Channel Intrinsic Security Power Supply, 4 to 20 mA, ATEX
- GEORGIN 2 Channel Intrinsic Security Power Supply, ATEX
- GEORGIN 2 Channel Intrinsic Security Power Supply, IECEx/ATEX
- GEORGIN Intrinsic Security Power Supply, IECEx/ATEX
- GEORGIN 2 Channel Intrinsic Security Power Supply, ATEX, IECEx LCI 09.0013X
- GEORGIN 2 Channel Intrinsic Security Power Supply, ATEX, IEC, IECEx LCI 09.0013X
- GEORGIN 2 Channel Intrinsic Security Power Supply, EN, CEI