SMC Vacuum Generator, 1.5 mm nozzle, -91 kPa 67 L/min, ZK2 series

Subtotal (1 unit)*

₩686,556.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 2 개 단위 배송 준비 완료
  • 추가로 2026년 5월 21일 부터 2 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩686,556.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
392-162
제조사 부품 번호:
ZK2A15K5RWA-06
제조업체:
SMC
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SMC

Product Type

Vacuum Generator

Maximum Suction Flow

67L/min

Maximum Vacuum Pressure

-91kPa

Nozzle Diameter

1.5mm

Series

ZK2

Silencer

Yes

Minimum Operating Temperature

+5°C

Vacuum Port Type

Plug Connection

Vacuum Port Size

6 mm

Maximum Supply Pressure

0.6MPa

Supply Port Type

Plug Connection

Supply Port Size

8 mm

Supply Port Thread Standard

PE

Maximum Operating Temperature

+50°C

Standards/Approvals

RoHS, CE

COO (Country of Origin):
JP

SMC ZK2 Series Vacuum Generator, 67L/min Maximum Suction Flow, -91kPa Maximum Vacuum Pressure - ZK2A15K5RWA-06


This vacuum generator is a compact, modular ejector unit designed for industrial automation and pneumatic systems. It provides a controlled vacuum source with integrated valves and a silenced exhaust, intended for use where a small footprint and electronic monitoring are required. The unit accepts a plug-in Air supply and offers a selectable pressure-sensing option with an LED display for straightforward monitoring.

Features & Benefits


• Maximum suction flow 67 L/min for steady component handling
• Nozzle diameter 1.5mm enabling fine vacuum control
• Maximum vacuum pressure -91 kPa for effective hold strength
• Supply pressure capability up to 0.6 MPa to match plant systems
• 8mm supply port with plug connection for quick piping
• 6mm plug connection vacuum port for one‑touch fittings

Applications


• Suitable for pick-and-place of small electronic components
• Ideal for end‑effector vacuum cups on assembly robots
• Used with pneumatic grippers in mechanical handling systems
• Can be used for packaging lines requiring Rapid vacuum cycles
• Suitable for testing rigs that need Compact vacuum sources

What electrical supply does the unit require for sensor operation?


The sensor and valve electronics operate from 12 to 24VDC with reverse-polarity protection and a ripple tolerance of 10% p‑p.

How is the vacuum level monitored and signalled?


A 3½‑digit red LED display shows measured pressure

outputs include a PNP open‑collector for general use and a dedicated valve-control output.

What environmental or durability limits should be observed?


Operate the unit between 5 °C and 50 °C

vibration and shock ratings are 20 m/s² and 100 m/s² respectively.

How fine is the pressure adjustment and repeatability?


The smallest set increment is 0.1 kPa with repeatability of ±0.2% F.S. ±1 digit and display accuracy ±2% F.S. ±1 digit.