Alpha Wire Alpha Essentials Communication & Control Series Control Cable, 1 Pairs, 0.56 mm², 30 m, Slate Sheath

Subtotal (1 reel of 305 metres)*

₩1,109,316.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 19 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
릴당
릴당
미터당*
1 +₩1,109,316.00₩3,636.75

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
277-3678
Distrelec 제품 번호:
300-99-356
제조사 부품 번호:
1896/4C SL001
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Product Type

Control Cable

Number of Pairs

1

Cross Sectional Area

0.56mm²

Cable Length

30m

Jacket Colour

Slate

Conductor Type

Copper

Minimum Operating Temperature

-20°C

Jacket Material

Polyvinyl Chloride

Maximum Operating Temperature

80°C

Standards/Approvals

UL AWM/STYLE 2509, California Proposition 65, EU 2011/65/EU(RoHS2), CSA International CMG, REACH Regulation (EC 1907/2006), EU Low Voltage 2014/35/EU, EU 2015/863/EU (RoHS3)

Series

Alpha Essentials Communication & Control

Voltage

300Vrms

Conductor Material

Tin Copper Wire

Fire Behaviour

FT4

제외

Belden Alpha Essentials Communication & Control Series Control Cable, 30m Cable Length, 0.56mm² Cross Sectional Area - 1896/4C SL001


This control cable provides a flexible connection for communication and control systems in industrial environments. It is designed for general-purpose signal and control wiring where a compact, multi-conductor cable with a PVC outer sheath is required. The construction supports moderate mechanical handling while maintaining electrical continuity for single-pair control circuits.

Features & Benefits


• Tin-plated copper conductors reduce corrosion and maintain conductivity
• Seven-strand conductors deliver improved flexing capability
• 0.56mm² conductor cross section supports typical control currents
• PVC jacket rated FT4 for enhanced vertical flame performance
• Operating range from -20°C to 80°C for varied site conditions

**Applications**


• Suitable for factory automation control panels and wiring
• Ideal for industrial sensor and actuator interconnections
• Used with Terminal blocks and PLC input/output wiring
• Can be used for machine tool signal cabling in workshops

What conductor construction enables repeated flexing?


Each conductor comprises seven tinned copper strands, which increase flexibility compared with solid wire and help resist breakage under repeated movement.

How is the cable marked for identification during installation?


The jacket is printed with manufacturer and type information alongside temperature and safety designations to assist identification on site.

What electrical characteristic is relevant for design calculations?


The nominal conductor DC resistance is approximately 10.2 Ω per 1000 ft at 20°C, useful for voltage-drop assessments in long runs.

What mechanical limits should installers observe when routing?


Maintain a bend radius of at least 10x the cable diameter and avoid exceeding a pull tension of 35 lb during installation.

Which regulatory restrictions apply to material composition?


The cable conforms to RoHS and REACH requirements and follows regional low-voltage and flame-performance specifications as part of its declared compliance.