Alpha Wire Alpha Essentials LSZH Communication & Control Series Data Cable, 2 Pairs, 0.35 mm², 305 m, Slate Sheath Low

Subtotal (1 reel of 305 metres)*

₩730,353.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 6월 02일 부터 1,830 개 단위 배송
  • 추가로 2026년 7월 14일 부터 2,135 개 단위 배송
  • 추가로 2026년 7월 21일 부터 1,525 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
릴당*
305 +₩2,394.60₩730,056.60

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
187-2075
제조사 부품 번호:
1173L SL001
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Number of Pairs

2

Product Type

Data Cable

Cross Sectional Area

0.35mm²

Cable Length

305m

Jacket Colour

Slate

Outside Diameter

4.27mm

Conductor Type

Copper

Jacket Material

Low Smoke Zero Halogen

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

75°C

Standards/Approvals

UL, CSA, CE

Core Strands

7

Series

Alpha Essentials LSZH Communication & Control

Conductor Material

Tin Copper Wire

Fire Behaviour

Low Smoke Zero Halogen (LSZH)

Voltage

300V

Belden Alpha Essentials LSZH Communication & Control Series Data Cable, 305m Cable Length, Slate Jacket - 1173L SL001


This data cable is a two-pair LSZH communication cable designed for controlled-environment signal and control runs in automation, electronics and electrical installations. It combines tin-plated multi-strand copper conductors with a low smoke zero halogen outer sheath to provide a compact, low-emission option for installations requiring moderate temperature operation.

Features & Benefits


• 0.35mm² tin copper conductors for corrosion resistance and flexibility
• 7-strand conductor construction for improved bend performance
• 300V rating for use in low-voltage control circuits
• Low smoke zero halogen jacket to limit toxic gas and corrosive residues
• 75°C maximum operating temperature for elevated ambient conditions

**Applications**


• Suitable for control-panel interconnects in factory automation
• Ideal for sensor and actuator wiring in machinery systems
• Used with building management and signalling circuits
• Can be used for internal wiring of electrical cabinets

What conductor construction assists routing through confined ducts?


The conductor comprises seven tinned copper strands per core, providing increased flexibility for tight bends and easier cable pulling.

How does the cable perform in fire-restricted environments?


The sheath formulation produces reduced smoke and minimal acid gas when exposed to flame, meeting relevant IEC tests for smoke and acid gas generation.

What packing options are available for site installation?


Standard continuous lengths include 100 ft, 500 ft and 1,000 ft reels, with bulk made-to-order options for larger projects.

What mechanical limitations should installers note during pulling?


Maintain a minimum bend radius of ten times the cable diameter and keep pull tensions below the specified maximum to avoid conductor damage.

How does the cable meet international acceptance for projects?


It carries recognised safety approvals and meets EU RoHS and REACH substance restrictions, supporting specification in multi-jurisdiction installations.

관련된 링크들