Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 3 Pairs, 0.23 mm², 305 m, Slate Sheath
- RS 제품 번호:
- 187-2023
- 제조사 부품 번호:
- 6073C SL001
- 제조업체:
- Alpha Wire
Subtotal (1 reel of 305 metres)*
₩3,296,853.30
현재 액세스할 수 없는 재고 정보 - 나중에 다시 확인해 주세요.
릴당 | 릴당 | 미터당* |
|---|---|---|
| 1 + | ₩3,296,853.30 | ₩10,808.85 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 187-2023
- 제조사 부품 번호:
- 6073C SL001
- 제조업체:
- Alpha Wire
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Alpha Wire | |
| Number of Pairs | 3 | |
| Product Type | Data Cable | |
| Cross Sectional Area | 0.23mm² | |
| Cable Length | 305m | |
| Jacket Colour | Slate | |
| Outside Diameter | 10.06mm | |
| Conductor Type | Copper | |
| Minimum Operating Temperature | -20°C | |
| Jacket Material | Polypropylene | |
| Maximum Operating Temperature | 75°C | |
| Standards/Approvals | CSA, UL, CE | |
| Fire Behaviour | FT4 | |
| Conductor Material | Tin Copper Wire | |
| Series | Alpha Essentials Communication & Control | |
| Voltage | 300V | |
| Core Strands | 7 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Alpha Wire | ||
Number of Pairs 3 | ||
Product Type Data Cable | ||
Cross Sectional Area 0.23mm² | ||
Cable Length 305m | ||
Jacket Colour Slate | ||
Outside Diameter 10.06mm | ||
Conductor Type Copper | ||
Minimum Operating Temperature -20°C | ||
Jacket Material Polypropylene | ||
Maximum Operating Temperature 75°C | ||
Standards/Approvals CSA, UL, CE | ||
Fire Behaviour FT4 | ||
Conductor Material Tin Copper Wire | ||
Series Alpha Essentials Communication & Control | ||
Voltage 300V | ||
Core Strands 7 | ||
Belden Alpha Essentials Communication & Control Series Data Cable, 305m Cable Length, 300V Voltage - 6073C SL001
This data cable provides three screened pairs for communication and control tasks in industrial environments. It combines tin‑plated copper conductors with a polypropylene outer jacket, delivering a balance of signal integrity and mechanical protection for medium‑distance wiring runs on reels up to 305 m. The cable is suitable for installation where regulated voltage ratings and recognised approvals are required.
Features & Benefits
• 7‑strand copper core offers flexible handling during installation
• 0.23 mm² conductor area supports consistent signal transmission
• Tin copper plating improves corrosion resistance for longevity
• 300V rating permits use in many control circuits
• FT4 fire behaviour reduces flame propagation in vertical shafts
• Slate polypropylene jacket resists environmental wear
• 0.23 mm² conductor area supports consistent signal transmission
• Tin copper plating improves corrosion resistance for longevity
• 300V rating permits use in many control circuits
• FT4 fire behaviour reduces flame propagation in vertical shafts
• Slate polypropylene jacket resists environmental wear
**Applications**
• Suitable for instrumentation and sensor cabling in factories
• Ideal for control panel internal wiring and signal routing
• Used with PLCs for short‑run communications in automation
• Can be used for building services where vertical fire performance is needed
• Suitable for OEM harnesses requiring flexible multi‑pair cable
• Ideal for control panel internal wiring and signal routing
• Used with PLCs for short‑run communications in automation
• Can be used for building services where vertical fire performance is needed
• Suitable for OEM harnesses requiring flexible multi‑pair cable
What is the twisting arrangement within the cable?
Each pair is constructed with two conductors cabled together and twisted at a minimum of 6.0 twists/ft, with the three components cabled together at a minimum of 3.0 twists/ft.
How is the cable shielded and terminated for earthing?
Pairs are wrapped with an aluminium/Mylar tape with 25% overlap and include a 24 AWG drain wire for shield termination.
What are the electrical characteristics relevant to signal performance?
Characteristic impedance is approximately 115 Ω ±5, mutual capacitance is around 12 pF/ft at 1 kHz, and velocity of propagation is 76%.
What mechanical limits should installers observe?
Recommended minimum bend radius is 10x cable diameter and maximum pull tension is 32 lbs.
Which standards and environmental directives apply to this cable?
It meets UL AWM/Style 2493, CSA CMG FT4, CE low‑voltage directives, and complies with RoHS and REACH substance limits.
관련된 링크들
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 13 Pairs, 0.08 mm², 305 m, Slate Sheath
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 1 Pairs, 0.81 mm², 305 m, Slate Sheath Polyvinyl
- Alpha Wire Alpha Essentials LSZH Communication & Control Series Data Cable, 2 Pairs, 0.35 mm², 305 m, Slate Sheath Low
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 3 Pairs, 30 m, Grey Sheath Polyvinyl Chloride
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable, 1 Pairs, 1.65 mm², 30 m, Slate Sheath Polyvinyl Chloride
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 3 Pairs, 0.08 mm², 305 m, Grey Sheath Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 3 Pairs, 0.23 mm², 305 m, Grey Sheath Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 2 Pairs, 0.35 mm², 305 m, Grey Sheath Polyvinyl