Alpha Wire Alpha Essentials Communication & Control Series Data Cable, 13 Pairs, 0.08 mm², 305 m, Slate Sheath

Subtotal (1 reel of 305 metres)*

₩11,086,140.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 8월 11일 부터 610 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
릴당*
305 +₩36,348.00₩11,086,140.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
187-2090
제조사 부품 번호:
6397 SL001
제조업체:
Alpha Wire
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Alpha Wire

Number of Pairs

13

Product Type

Data Cable

Cross Sectional Area

0.08mm²

Cable Length

305m

Jacket Colour

Slate

Outside Diameter

9.19mm

Conductor Type

Copper

Minimum Operating Temperature

-20°C

Jacket Material

Polyethylene

Maximum Operating Temperature

+75°C

Standards/Approvals

CSA, CE, UL

Conductor Material

Tin Copper Wire

Series

Alpha Essentials Communication & Control

Fire Behaviour

Flammability Test: VW-1

Core Strands

7

Voltage

300V

Belden Alpha Essentials Communication & Control Series Data Cable, 305m Cable Length, 13 Pairs - 6397 SL001


This data cable is a multi-pair communication cable designed for industrial control and signal transmission in automation and electrical systems. It combines 13 twisted pairs of tin‑plated copper conductors within a shielded assembly and a slate-coloured outer jacket to provide organised multi-signal routing and protection in installations requiring extended continuous lengths.

Features & Benefits


• 13 pairs deliver dense multi-channel signal distribution
• 7-strand tinned copper conductors improve flexibility and conductivity
• 0.08mm² conductor area supports low-voltage signalling at 300V
• Shielding with foil, drain and 90% braid reduces EMI in noisy environments
• Polyethylene and PVC construction tolerates operating temperatures from -20 to +75°C
• VW-1 flammability rating provides flame-retardant performance for routed runs

**Applications**


• Suitable for factory automation signal cabling between controllers and I/O
• Ideal for multi-channel instrumentation and sensor arrays
• Used for control-panel internal wiring where Compact pair count is required
• Can be used for building management systems with multiple discrete circuits

How are the individual pairs insulated and arranged inside the cable?


Each pair uses nominal polyethylene insulation with standard colour coding and is cabled two conductors per pair with controlled pair and overall twists to maintain pair integrity.

What form of shielding is provided and how does it aid termination?


The assembly includes aluminium/mylar tape with a drain conductor Plus a tinned-copper braid at a minimum 90% coverage to present a low-resistance shield for earthing and improved common-mode noise rejection.

What packaging lengths are available for continuous runs?


The cable is offered in continuous lengths on reels including 100m, 500m and 1000ft/305m options to support long installation runs.

What mechanical limits should installers observe during pulling?


The cable has a recommended minimum bend radius of 10x the cable diameter and a maximum pull tension of 46 lb to avoid conductor or jacket damage.