Fluke calibration Temperature Calibrator Accessory, For Use With 9009 Industrial Dual-Block Dry-Well

Subtotal (1 unit)*

₩354,360.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 12월 10일 부터 1 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩354,360.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
284-2710
Distrelec 제품 번호:
301-35-893
제조사 부품 번호:
3102-6
제조업체:
Fluke calibration
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke calibration

Product Type

Temperature Calibrator Accessory

Accessory Type

Insert

For Use With

9009 Industrial Dual-Block Dry-Well

Standards/Approvals

No

COO (Country of Origin):
US

Fluke Temperature Calibrator Accessory, 9009 Compatible Device, Insert Accessory Type - 3102-6


This temperature calibrator accessory is an insert designed for use with a 9009 industrial dual-block dry-well. It functions as a replaceable component that fits into a dual-block dry-well system to support temperature calibration tasks in industrial environments. The accessory facilitates the insertion of devices under test into a controlled thermal cavity maintained by the parent dry-well unit.

Features and Benefits:


• Precision fit to host cavity ensures consistent thermal contact
• Compatible with dual-block architecture for simultaneous testing
• Enables straightforward replacement to minimise instrument downtime
• Constructed for integration with industrial dry-well systems
• Supports repeatable positioning to improve calibration reproducibility

Applications


• Suitable for insertion into 9009 industrial dual-block dry-well
• Used with temperature calibration setups in maintenance labs
• Ideal for routine field calibration of thermometers and probes
• Can be used for comparative checks between sensors simultaneously
• Used for replacing worn inserts to restore dry-well capability

How does it affect calibration turnaround times?


Replacing the insert restores correct probe positioning quickly, reducing equipment out-of-service time and allowing faster resumption of calibration sequences.

What compatibility considerations are there when selecting an insert?


Ensure the insert is specified for dual-block dry-well use and matches the host cavity geometry to maintain thermal interchange and probe contact reliability.

How does the insert influence thermal performance of the dry-well?


It provides the interface between the heated block and device under test, so its fit and material properties directly impact heat transfer uniformity and measurement repeatability.

Is this accessory intended for single- or multi-sensor checks?


It is designed to work within a dual-block dry-well environment, enabling simultaneous accommodation of multiple sensors for comparative or batch calibration tasks.

관련된 링크들