Eaton 400A Tag Fuse NH3 1000V, 112 mm

Subtotal (1 unit)*

₩937,142.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2027년 3월 22일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩937,142.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
282-6190
제조사 부품 번호:
BSF-400G-NH310-B
제조업체:
Eaton
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Eaton

Product Type

Tag Fuse

Current Rating

400A

Fuse Size

NH3

Voltage

1000V

Standards/Approvals

IEC 60269-7

Fixing Centres

112 mm

Application Category

Battery Storage

Fuse Speed

Fast Acting

High Rupture Capacity

Yes

Length

150mm

Overall Length

150mm

Width

71mm

Height

76mm

Series

Bussmann

COO (Country of Origin):
IN

Eaton Tag Fuse, 400A Current, 1000V Voltage - BSF-400G-NH310-B


This tag fuse is designed to protect and isolate battery arrays within storage systems, interrupting low overcurrents and reverse currents typical of multi-array faults. It operates at high voltage for DC battery installations and pairs with compatible NH bases and fuse-holders for secure integration in industrial electrical layouts.

Features & Benefits


• 1000V rated voltage provides high-voltage DC protection
• 400A current rating for high-capacity battery circuits
• Fast-acting operation limits fault energy in seconds
• High rupture capacity 100 kA interrupts severe faults
• Dual indicator feature offers clear operational status
• Broad compatibility with NH bases and holders

Applications


• Suitable for battery-array combiners and disconnects in storage systems
• Ideal for photovoltaic storage installations requiring DC protection
• Used with NH fuse-holders in industrial electrical switchgear
• Can be used for multi-string battery-bank protection in renewable projects

What fixing arrangement does it use for panel mounting?


It is designed for 112mm fixing centres to align with standard NH mounting provisions.

How long is the unit for physical space planning?


The overall length is 150 mm, enabling planning of fuse-bay spacing.

Which fuse body size is specified for higher current capacity?


The body conforms to NH3 sising to accommodate 400A performance and related mechanical interfaces.

What performance data describes its thermal and breaking behaviour?


Time constant is 4.5 MS at 100 kA and breaking capacity is rated at 100 kA for Peak interruption calculations.

What ancillary items are required for microswitch monitoring and mounting?


Specific microswitches and bolt/blade holders are available as separate orders for the bladed variant.