SICK i16 Safety Interlock Switch, Polybutylene Terephthalate

Subtotal (1 unit)*

₩95,000.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 20 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩95,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9589
제조사 부품 번호:
i16-SA203
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

2 NC

Housing Material

Polybutylene Terephthalate

Series

i16

Switch Contact Current

3A

Minimum Operating Temperature

-20°C

Contact AC Voltage

240V ac

IP Rating

IP67

Contact DC Voltage

24V dc

Hazardous Area Certification

No

Maximum Operating Temperature

80°C

Standards/Approvals

IEC 60529

Number of Head Directions

3

Depth

32mm

Length

75mm

Width

52mm

COO (Country of Origin):
DO

SICK i16 Series Safety Interlock Switch, 3A Rated Current, IP67 - i16-SA203


This safety interlock switch provides mechanical guard monitoring for industrial safety systems. It employs positive-action contacts to signal guard position changes and is intended for hardwired diagnostic architectures. The device is built for use where environmental ingress protection and temperature resilience are required, and it operates with an electro-mechanical switching mechanism suitable for routine access control tasks.

Features and Benefits:


• 2NC safety contacts provide force-guided switching for fault tolerance
• 3A rated current supports 240V AC industrial control loads
• IP67 enclosure protects against dust and temporary immersion
• Polybutylene terephthalate housing resists mechanical and thermal stress
• Operates between -20°C and 80°C for varied ambient conditions

Applications


• Suitable for machine guard monitoring in manufacturing cells
• Ideal for conveyor access and interlock safety circuits
• Used with safety logic units for diagnostic fault processing
• Can be used for production line access doors and covers
• Suitable for environments requiring actuatorless safety interlock switch

What connection method does it use?


It connects via three M20 cable gland entries supporting conductors up to 1.5mm².

How is the safe state handled in case of an internal fault?


The switch itself has no internal fault detection, so the connected safety logic must perform fault monitoring.

What are the electrical switching thresholds for low-voltage signalling?


The switching element operates down to 5V DC and switches currents as low as 5mA.

How Durable is the mechanism under mechanical cycling?


Mechanical life is specified as 1x10⁶ switching cycles with defined retaining force limits.