SICK i16 Safety Interlock Switch, Polybutylene Terephthalate

Subtotal (1 unit)*

₩95,000.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 09일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩95,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9588
제조사 부품 번호:
i16-SA113
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Safety Contacts

1 NO/1 NC

Housing Material

Polybutylene Terephthalate

Series

i16

IP Rating

IP67

Contact AC Voltage

240V ac

Contact DC Voltage

24V dc

Switch Contact Current

2A

Minimum Operating Temperature

-20°C

Hazardous Area Certification

No

Maximum Operating Temperature

80°C

Length

75mm

Number of Head Directions

3

Width

52mm

Standards/Approvals

IEC 60529

Depth

32mm

COO (Country of Origin):
DO

SICK i16 Series Safety Interlock Switch, IP67, 1 NO 1 NC Safety Contacts - i16-SA113


This safety interlock switch is an electro‑mechanical device designed to monitor access points and protect machinery by detecting actuator position. It operates reliably across a wide ambient temperature range and is intended for integration with safety logic units where internal fault detection is not provided. The unit is supplied without an actuator and connects via three M20 cable glands for field wiring.

Features and Benefits:


• IP67 enclosure rating provides dust and water protection for harsh environments
• 1 NO 1 NC contacts enable discrete safety signalling and control
• 2A switching current supports 24V DC control circuits
• 240V AC rated contact handles standard control voltages
• Retaining force ≤30N minimises accidental release during operation

Applications


• Used for safeguarding interlocked guards on production lines
• Suitable for integration with safety controllers in factories
• Ideal for machine doors requiring dust and water resistance
• Used with low‑coding actuators in Basic safety
• Can be used for monitoring access in conveyor systems

What wiring Interface does it provide for installation?


It uses three M20 cable gland entries and accepts conductors up to ≤1.5mm².

How does the device behave in the event of an internal fault?


The switch has no internal fault detection

fault monitoring must be performed by the connected safety logic unit.

What mechanical endurance can I expect for frequent operations?


Mechanical life is specified as 1x10⁶ switching cycles under normal conditions.

Are there limits on actuation speed and frequency?


Actuation speed must not exceed 10m/min and may be operated up to 7,200 cycles per hour.