SICK i110 Safety Interlock Switch, Die Cast Zinc

Subtotal (1 unit)*

₩361,740.00

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 5 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩361,740.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9576
제조사 부품 번호:
i110-RP223
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Interlock Switch

Actuator Included

No

Housing Material

Die Cast Zinc

Series

i110

Switch Contact Current

3A

Contact DC Voltage

24V dc

IP Rating

IP66

Contact AC Voltage

240V ac

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

80°C

Hazardous Area Certification

No

Depth

56mm

Width

40mm

Length

204mm

Standards/Approvals

IEC 60529

Number of Head Directions

1

COO (Country of Origin):
DO

SICK i110 Series Safety Interlock Switch, 3A Rated Operating Current, IP66 - i110-RP223


This safety interlock switch is a Compact device designed to monitor access points and interrupt hazardous movements in industrial settings. It provides slow-action switching with positive-action contacts and connects via a single M20 cable gland. The unit is intended for individual wiring with diagnostics handled by external safety logic and operates across a wide ambient temperature range.

Features and Benefits:


• 3A rated operating current for 240V AC and 24V DC applications
• IP66 enclosure rating for dust-tight and powerful jet protection
• Positive-action contacts ensure defined switching behaviour
• Mechanical life of 1x10^6 switching cycles for sustained use
• Cable length capability up to 30m enabling remote actuation

Applications


• Used for guarding access points on production lines
• Suitable for rope-pull safety implementations in factories
• Ideal for integration with external safety logic units
• Can be used where a Compact interlock switch 204mm is required
• Used where hazardous-area non-certified interlock hardware is acceptable

What contact arrangements does it provide?


It contains two positive-action N/C contacts and two N/O contacts enabling mixed circuit configurations.

How is the device connected electrically?


Wiring is via a single M20 cable gland supporting conductors up to 1.5mm².

What environmental extremes can it tolerate?


It operates between -25°C and +80°C and can be stored within the same temperature limits.

Is the actuator included with the unit?


No, the actuator is not included and must be supplied separately.

How is short-circuit protection handled?


Short-circuit protection requires a T6 fuse rating as specified for the device.