SICK i110 Safety Interlock Switch, Power, Fibreglass Reinforced Thermoplastic, Electromagnetic

Subtotal (1 unit)*

₩657,020.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 17일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩657,020.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-9569
제조사 부품 번호:
i110-E0313S06
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Interlock Switch

Lock Style

Power

Lock Type

Electromagnetic

Actuator Included

No

Safety Contacts

2 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

i110

Switch Contact Current

4A

IP Rating

IP67

Contact DC Voltage

24V dc

Minimum Operating Temperature

-20°C

Contact AC Voltage

230V ac

Maximum Operating Temperature

55°C

Hazardous Area Certification

No

Depth

40mm

Number of Head Directions

5

Length

190mm

Width

42mm

Standards/Approvals

IEC 60529

COO (Country of Origin):
DE

SICK i110 Series Safety Interlock Switch, 4A Switch Contact Current, IP67 - i110-E0313S06


This safety interlock switch provides electro-mechanical access control for machinery guards, using a power-to-lock electromagnetic mechanism and designed for industrial environments. It is enclosed in a glass-fibre reinforced thermoplastic housing and intended for connection via three M20 cable glands. The unit operates with diagnostic-capable individual wiring and requires an actuator (not supplied) to function.

Features and Benefits:


• 2NC safety contacts deliver monitored normally-closed switching integrity
• 4A contact current supports 230V AC and 24V DC applications
• Power-to-lock principle provides 2,500N maximum locking force
• IP67 enclosure rating enables use in harsh, contaminated settings
• Five actuation directions allow flexible guard alignment

Applications


• Suitable for guarding on automated production lines
• Ideal for integration with safety logic units for diagnostics
• Used with interlocked doors on material handling equipment
• Can be used for perimeter protection in machine cells
• Suitable for environments requiring dust and water resistance

What electrical interfaces are available for connection?


It uses electro-mechanical contacts with three M20 cable glands and accepts conductor sizes 0.34mm² to 1.5mm².

How does the device behave if an internal fault occurs?


The switch contains no internal fault detection and relies on the external safety-related logic unit for fault monitoring.

What are the thermal operating limits for duty planning?


The ambient operating and storage temperature range is -20°C to +55°C.

What mechanical lifecycle can be expected under small loads?


The device has a mechanical life of 1x10^5 switching cycles and a B10d Value of 5x10^6 switching cycles for small loads.