Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator

Subtotal (1 unit)*

₩7,050,771.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 7월 31일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩7,050,771.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
623-9901
제조사 부품 번호:
FLUKE-718 1G/APAC
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Battery Type

Alkaline

Product Type

Pressure Calibrator

Maximum Pressure Measurement

68.9mbar

Accuracy

±0.025 %

Minimum Pressure Measurement

-68.9mbar

Resolution

0.001 mbar

Pressure Port Type

Gauge

Data Logging

No

Model Number

718

Intrinsically Safe

No

Display Type

LCD

Current Loop Measurement

Yes

Power Source

Battery

Weight

992g

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Battery Life

20h

Standards/Approvals

No

Length

216mm

Width

94mm

Height

66mm

Hazardous Area Certification

No

제외

COO (Country of Origin):
CN

Fluke Pressure Calibrator, ±0.025% Accuracy, 68.9 m Bar Maximum Pressure Measurement - FLUKE-718 1G


This handheld pressure calibrator provides a compact, portable solution for pressure transmitter, gauge and switch calibration in industrial settings. It combines a pressure source with milliamp measurement and an integrated pump designed for easy maintenance after exposure to process fluids, enabling on-site calibration and troubleshooting across automation, electrical, electronics and mechanical environments.

Features & Benefits


• Resolution 0.001 mbar improves fine low-pressure adjustments
• Accuracy ±0.025% delivers precise full-span measurements
• Battery powered pressure calibrator 20 h life supports long field shifts
• LCD pressure calibrator Alkaline battery simplifies status monitoring
• Maximum pressure measurement ±68.9 mbar covers low-pressure work
• Error percentage calculation speeds pass/fail decision making

**Applications**


• Suitable for calibrating pressure transmitters in process control systems
• Ideal for testing pressure switches on pneumatic control panels
• Used with pressure gauges during installation and commissioning checks
• Can be used for field loop checks with 4–20 mA devices
• Used for maintenance of HVAC and low-pressure instrumentation

What power source and battery arrangement does it use?


It runs from alkaline 9V batteries with two cells in the instrument and typical run time up to 20 h depending on functions used.

How does the pump handle accidental fluid exposure?


The pump features protective check valves and a removable valve assembly allowing field cleaning of springs and O-rings to remove residue without full disassembly.

What environmental conditions can it tolerate during operation?


It operates between -10 °C and 55 °C, withstands random vibration at 2 g from 5 Hz–500 Hz and survives a 1m drop test.

What simultaneous measurements are displayed?


The LCD shows five-digit pressure and current values at the same time for combined pressure and milliamp readings.

How Compact and portable is the instrument for site work?


The unit with holster measures 216mm x 94mm x 66mm and weighs 992 g for convenient handheld use.

Standards

CSA C22.2 no. 1010.1: 1992, IEC 61010, CAT I 30V

Supplied with

Fluke 718, holster, TL75 test leads, AC72 crocodile clips, two 9 V batteries, instruction manual