PicoScope 4000A Series, 20 MHz PC Based PC Oscilloscope 4-Channel

Subtotal (1 unit)*

₩2,737,260.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 12 개 단위 배송 준비 완료
  • 추가로 2026년 11월 25일 부터 6 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,737,260.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
218-2727
Distrelec 제품 번호:
301-96-821
제조사 부품 번호:
PicoScope 4424A
제조업체:
Pico Technology
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pico Technology

Product Type

PC Oscilloscope

Bandwidth

20MHz

Number of Channels

4

Model Number

PicoScope 4424A

Oscilloscope Type

PC Based

Interface Type

USB

Series

PicoScope 4000A

Height

40mm

Width

170mm

Length

190mm

Standards/Approvals

RoHS, WEEE

Minimum Vertical Sensitivity

2mV/div

Power Source

USB

Vertical Resolution

12 bit

Minimum Time Base

20ns/div

Maximum Time Base

5000s/div

Maximum Vertical Sensitivity

10V/div

Rise Time

17.5ns

COO (Country of Origin):
GB

PicoScope 4000A Series Pc Oscilloscope, 20MHz Bandwidth, 4 Channels - PicoScope 4424A


This PC oscilloscope connects to a computer via USB to perform waveform capture and analysis within laboratory and field environments. It is a compact, USB‑powered, PC‑based instrument designed for multichannel signal observation, featuring a moderate bandwidth suited to low‑frequency diagnostics and development tasks. The unit is supplied with environmental compliance credentials appropriate for electronics workplaces.

Features and Benefits:


• 12‑bit vertical resolution delivers finer amplitude discrimination
• 2 mV/div sensitivity enables measurement of small signals
• 20 ns/div minimum time base supports short event capture
• 17.5 ns rise time resolves fast signal transitions
• Four independent channels allow simultaneous multi‑point monitoring

Applications


• Suitable for routine analogue circuit troubleshooting
• Ideal for low‑frequency signal characterisation
• Used for multi‑channel sensor signal validation
• Can be used for debugging USB‑powered test set‑ups

How is the device powered during operation?


It draws all operating power through the USB Interface so no external PSU is required.

What resolution should I expect for amplitude measurements?


The instrument uses a 12‑bit vertical converter to provide enhanced amplitude resolution for detailed analysis.

What temporal resolution is available for capturing transient events?


The minimum selectable time base is 20 ns/div enabling capture of brief waveform features.

How many channels are available for concurrent acquisition?


There are four independent input channels for simultaneous signal acquisition.

Which environmental standards does the unit meet?


The product complies with RoHS and WEEE environmental disposal and materials directives.