Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 20.4 → 26.4 V dc, 26.4V ac
- RS 제품 번호:
- 111-3094
- 제조사 부품 번호:
- K8DT-AS2TD
- 제조업체:
- Omron
Subtotal (1 unit)*
₩324,680.00
재고있음
- 2 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩324,680.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 111-3094
- 제조사 부품 번호:
- K8DT-AS2TD
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | SPST | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 0.1A | |
| Maximum Current Sensed | 5A | |
| Power Consumption | 1.8VA | |
| Current Sensitivity | Undercurrent, Overcurrent | |
| Terminal Type | Push-in | |
| Time Delay | 250 ms | |
| IP Rating | IP20 | |
| Supply AC Voltage | 26.4V ac | |
| Supply DC Voltage | 20.4 → 26.4 V dc | |
| Relay Contact Current | 0.1, 5A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Length | 90mm | |
| Series | K8DT-AS | |
| Width | 17.5mm | |
| Standards/Approvals | UL 60947-5-1, RoHS, EN 60947-5-1 | |
| Height | 90mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration SPST | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 0.1A | ||
Maximum Current Sensed 5A | ||
Power Consumption 1.8VA | ||
Current Sensitivity Undercurrent, Overcurrent | ||
Terminal Type Push-in | ||
Time Delay 250 ms | ||
IP Rating IP20 | ||
Supply AC Voltage 26.4V ac | ||
Supply DC Voltage 20.4 → 26.4 V dc | ||
Relay Contact Current 0.1, 5A | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Length 90mm | ||
Series K8DT-AS | ||
Width 17.5mm | ||
Standards/Approvals UL 60947-5-1, RoHS, EN 60947-5-1 | ||
Height 90mm | ||
- COO (Country of Origin):
- CN
Omron K8DT-AS Series Monitoring Relay, 20.4-26.4V Supply Voltage, 0.1-5A Current Sensing Range - K8DT-AS2TD
This monitoring relay provides current sensing for single-phase systems, delivering both undercurrent and overcurrent detection within industrial control panels. It accepts either AC or DC control supplies in the 20.4-26.4V range, mounts on DIN rail and is intended for straightforward integration into automation and electrical monitoring arrangements.
Features and Benefits:
• Detects currents from 0.1A to 5A for precise protection and monitoring
• Configured as SPST to simplify wiring and contact logic
• 250 MS time delay to prevent nuisance tripping from transients
• Push-in terminals to speed installation and reduce tool use
• Accepts AC and DC control voltages 20.4-26.4V to suit mixed systeMS
• Power consumption 1.8VA to assist energy-conscious panel design
• Configured as SPST to simplify wiring and contact logic
• 250 MS time delay to prevent nuisance tripping from transients
• Push-in terminals to speed installation and reduce tool use
• Accepts AC and DC control voltages 20.4-26.4V to suit mixed systeMS
• Power consumption 1.8VA to assist energy-conscious panel design
Applications
• Suitable for motor load monitoring to signal stalled or light-load conditions
• Ideal for control-circuit protection in factory automation systems
• Used with switchboards requiring Compact current supervision
• Can be used for preventive maintenance alarm signalling in plant equipment
• Ideal for control-circuit protection in factory automation systems
• Used with switchboards requiring Compact current supervision
• Can be used for preventive maintenance alarm signalling in plant equipment
What ambient conditions can it operate within?
It functions across a temperature range from -20 °C to 60 °C, suitable for typical indoor industrial environments.
How is the device secured inside a control cabinet?
It is designed for DIN-rail mounting enabling straightforward rail-clip installation and removal.
What environmental protection level does the enclosure provide?
The unit carries an IP20 rating, offering Basic protection against access to live parts in enclosed panels.
Which electrical phase does it monitor and how does that affect application?
It monitors a single electrical phase, making it appropriate for single-phase loads and control circuits.
Note
K8DT-AS allow use in either overcurrent or undercurrent mode.
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
Standards
EN 60947-5-1, UL 60947-5-1, IP 20 Terminals
관련된 링크들
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 10A to 200A, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0V ac 0 V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0 V ac, 0V ac
- Omron Monitoring Relay, 3 Phase, SPST, DIN Rail
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0V ac
- Omron Monitoring Relay, SPST, DIN Rail, Monitoring: 0 °C to 999 °C, 0 V ac 0V ac