Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 20.4 → 26.4 V dc, 26.4V ac
- RS 제품 번호:
- 111-3090
- 제조사 부품 번호:
- K8DT-AS1TD
- 제조업체:
- Omron
Subtotal (1 unit)*
₩262,460.00
일시적 품절
- 2026년 10월 05일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩262,460.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 111-3090
- 제조사 부품 번호:
- K8DT-AS1TD
- 제조업체:
- Omron
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Omron | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1 | |
| Contact Configuration | SPST | |
| Mount Type | DIN Rail | |
| Minimum Current Sensed | 2mA | |
| Power Consumption | 1.8VA | |
| Maximum Current Sensed | 500mA | |
| Current Sensitivity | Overcurrent, Undercurrent | |
| Terminal Type | Push-in | |
| Time Delay | 250 ms | |
| IP Rating | IP20 | |
| Supply DC Voltage | 20.4 → 26.4 V dc | |
| Relay Contact Current | 2, 500mA | |
| Supply AC Voltage | 26.4V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Height | 90mm | |
| Series | K8DT-AS | |
| Standards/Approvals | EN 60947-5-1, RoHS, UL 60947-5-1 | |
| Width | 17.5mm | |
| Length | 90mm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Omron | ||
Product Type Monitoring Relay | ||
Electrical Phase 1 | ||
Contact Configuration SPST | ||
Mount Type DIN Rail | ||
Minimum Current Sensed 2mA | ||
Power Consumption 1.8VA | ||
Maximum Current Sensed 500mA | ||
Current Sensitivity Overcurrent, Undercurrent | ||
Terminal Type Push-in | ||
Time Delay 250 ms | ||
IP Rating IP20 | ||
Supply DC Voltage 20.4 → 26.4 V dc | ||
Relay Contact Current 2, 500mA | ||
Supply AC Voltage 26.4V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Height 90mm | ||
Series K8DT-AS | ||
Standards/Approvals EN 60947-5-1, RoHS, UL 60947-5-1 | ||
Width 17.5mm | ||
Length 90mm | ||
- COO (Country of Origin):
- CN
Omron K8DT-AS Series Monitoring Relay, 20.4-26.4V Supply Voltage, 250ms Time Delay - K8DT-AS1TD
This monitoring relay provides compact, DIN-rail-mounted detection and signalling of current deviations in single-phase systems. It operates from low-voltage AC or DC supplies and responds to both excessive and insufficient current to protect equipment and trigger control logic in automation and electrical installations.
Features and Benefits:
• Detects overcurrent and undercurrent to prevent system faults
• Switches SPST contacts for simple on/off control integration
• Accepts 20.4 to 26.4V AC/DC supply for flexible power options
• Senses currents from 2 mA up to 500 mA for fine resolution
• 250 MS time delay to avoid nuisance trips from transients
• Push-in terminals speed installation and wiring changes
• Switches SPST contacts for simple on/off control integration
• Accepts 20.4 to 26.4V AC/DC supply for flexible power options
• Senses currents from 2 mA up to 500 mA for fine resolution
• 250 MS time delay to avoid nuisance trips from transients
• Push-in terminals speed installation and wiring changes
Applications
• Suitable for motor load monitoring to identify stalled conditions
• Ideal for conveyor systems requiring phase-limited current supervision
• Used with control panels for process automation alarm signalling
• Can be used for monitoring current draw on single-phase pumps
• Suitable for retrofit protection on small machinery in workshops
• Ideal for conveyor systems requiring phase-limited current supervision
• Used with control panels for process automation alarm signalling
• Can be used for monitoring current draw on single-phase pumps
• Suitable for retrofit protection on small machinery in workshops
What Terminal arrangement is provided for quick wiring?
It uses push-in type connections that allow tool-free conductor insertion and secure contact retention for efficient assembly.
What environmental limits should be observed during installation?
The unit is designed to operate between -20°C and 60°C and has IP20 ingress protection, so it requires an enclosed control cabinet in dusty or humid locations.
How does the relay indicate or act when current thresholds are crossed?
A single-pole single-throw contact changes state when measured current falls below or exceeds set limits, enabling external alarms or PLC inputs to respond.
What mounting method is required for panel integration?
The device clips onto a standard DIN rail for straightforward mounting within electrical enclosures.
What electrical phase and power consumption characteristics apply?
It monitors single-phase systems and consumes 1.8 VA during operation.
Note
K8DT-AS allow use in either overcurrent or undercurrent mode.
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
K8DT-AW allow overcurrent and undercurrent monitoring simultaneously
Standards
EN 60947-5-1, UL 60947-5-1, IP 20 Terminals
관련된 링크들
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0.1A to 5A, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 10A to 200A, 0 V ac, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 2mA to 500mA, 0V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0V ac 0 V ac
- Omron Monitoring Relay, 1 Phase, SPST, DIN Rail, 0V ac
- Omron Monitoring Relay, SPST, DIN Rail, Monitoring: 0 °C to 999 °C, 0 V ac 0V ac
- Omron Monitoring Relay, 3 Phase, SPST, DIN Rail