Dold Insulation Monitor, DIN Rail, 85 V dc, 230 V ac
- RS 제품 번호:
- 339-003
- 제조사 부품 번호:
- UH5892.11PS UH=AC/DC85-230V 50kOhm
- 제조업체:
- Dold
Subtotal (1 unit)*
₩996,698.92
재고있음
- 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩996,698.92 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 339-003
- 제조사 부품 번호:
- UH5892.11PS UH=AC/DC85-230V 50kOhm
- 제조업체:
- Dold
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Dold | |
| Product Type | Insulation Monitor | |
| Mount Type | DIN Rail | |
| Switching Voltage | 250 V ac | |
| Power Consumption | 1.5W | |
| IP Rating | IP20, IP40 | |
| Supply DC Voltage | 85 V dc | |
| Relay Contact Current | 5 A | |
| Minimum Operating Temperature | -25°C | |
| Supply AC Voltage | 230 V ac | |
| Maximum Operating Temperature | 60°C | |
| Height | 107mm | |
| Width | 45 mm | |
| Series | UH5892 | |
| Length | 121mm | |
| Standards/Approvals | IEC/EN 60947-5-1 | |
| 모두 선택 | ||
|---|---|---|
브랜드 Dold | ||
Product Type Insulation Monitor | ||
Mount Type DIN Rail | ||
Switching Voltage 250 V ac | ||
Power Consumption 1.5W | ||
IP Rating IP20, IP40 | ||
Supply DC Voltage 85 V dc | ||
Relay Contact Current 5 A | ||
Minimum Operating Temperature -25°C | ||
Supply AC Voltage 230 V ac | ||
Maximum Operating Temperature 60°C | ||
Height 107mm | ||
Width 45 mm | ||
Series UH5892 | ||
Length 121mm | ||
Standards/Approvals IEC/EN 60947-5-1 | ||
- COO (Country of Origin):
- DE
The Dold insulation monitor of the series varimeter IMD monitors the ground resistance of isolated DC-voltage systems (IT-systems) with nominal voltage up to DC 600 V. The unit detects symmetrical as well as unsymmetrical faults. The separate auxiliary supply of AC/DC 24 to 60 V or AC/DC 85 to 230 V allows also monitoring when the system is without voltage. To indicate the actual ground resistance value the unit has an LED chain and an analogue output. When a fault is detected the relay switches and the red LED Alarm lights up, The device can be used for system with leakage capacities up to 20 uF.
Response value type Fixed
Enclosure design Switch cabinet
관련된 링크들
- Dold Insulation Monitor, SPDT, DIN Rail, 2A to 5A, 500 to 1000 V dc, 400/690 V ac
- Dold Insulation Monitor, SPDT, DIN Rail, 2A to 5A, 500 to 1500 V dc, 400/100 V ac
- Dold Monitoring Relay, SPDT, DIN Rail 220 V dc
- Dold Monitoring Relay, 3 Phase, 0.7 to 1.3 UN Monitor Range, DPDT, DIN Rail 80 to 230 V dc
- Dold Monitoring Relay, 1, 3 Phase, SPDT, DIN Rail, 230 V ac
- Dold Monitoring Relay, 3 Phase, DIN Rail, 24 V dc, 230 V ac
- Dold Monitoring Relay, 3, 1 Phase, 0 to 500 V Monitor Range, DPDT, DIN Rail 110 to 240 V dc
- Dold Monitoring Relay, 3 Phase, 0.7 to 1.1 UN Monitor Range, DPDT, DIN Rail