Dold Insulation Monitoring Relay, 1, 3 Phase, SPDT, 0.8 → 1.1 V, DIN Rail
- RS 제품 번호:
- 240-9033
- 제조사 부품 번호:
- AI897 AC45-400Hz230V 10-80kOhm
- 제조업체:
- Dold
Subtotal (1 unit)*
₩490,202.48
재고있음
- 4 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩490,202.48 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 240-9033
- 제조사 부품 번호:
- AI897 AC45-400Hz230V 10-80kOhm
- 제조업체:
- Dold
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Dold | |
| Monitoring Application | Insulation | |
| Electrical Phase | 1, 3 | |
| Voltage Sensing Range | 0.8 → 1.1 V | |
| Contact Configuration | SPDT | |
| Mounting Type | DIN Rail | |
| Time Delay | <4.2s | |
| Series | AI 897 | |
| Width | 45mm | |
| Maximum Operating Temperature | +60°C | |
| Dimensions | 115 x 45 x 77mm | |
| Operating Temperature Range | +60°C | |
| Length | 115mm | |
| Height | 77mm | |
| Minimum Operating Temperature | -20°C | |
| 모두 선택 | ||
|---|---|---|
브랜드 Dold | ||
Monitoring Application Insulation | ||
Electrical Phase 1, 3 | ||
Voltage Sensing Range 0.8 → 1.1 V | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay <4.2s | ||
Series AI 897 | ||
Width 45mm | ||
Maximum Operating Temperature +60°C | ||
Dimensions 115 x 45 x 77mm | ||
Operating Temperature Range +60°C | ||
Length 115mm | ||
Height 77mm | ||
Minimum Operating Temperature -20°C | ||
- COO (Country of Origin):
- DE
Insulation monitor for pure 3 phase and alternating current systems, AI897
Adjustable response value 10 → 80 kΩ
No separate auxiliary voltage connection required
1 changeover
Overall width 45 mm
No separate auxiliary voltage connection required
1 changeover
Overall width 45 mm
The AI897 insulation monitor displays the insulation resistance of unearthed 3 phase and alternating current systems to earth.
The device works according to the quiescent current principle, that is, the output relay responds when mains voltage is applied to terminals A1 → A2. The output relay breaks when the response setpoint is undercut.
A bridge between terminals LT1 and LT2 allows the AI897 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. There is a PT test button on the front of the device to test for functional efficiency. An external test button (in accordance with VDE 0413) is also possible.
The device works according to the quiescent current principle, that is, the output relay responds when mains voltage is applied to terminals A1 → A2. The output relay breaks when the response setpoint is undercut.
A bridge between terminals LT1 and LT2 allows the AI897 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. There is a PT test button on the front of the device to test for functional efficiency. An external test button (in accordance with VDE 0413) is also possible.

관련된 링크들
- Dold Insulation Monitoring Relay, SPDT, 0.8 → 1.1 V, DIN Rail
- Dold Frequency Monitoring Relay, SPDT, DIN Rail
- Dold Insulation Monitoring Relay, 1, 3 Phase, SPDT, 0 → 500V ac, DIN Rail
- Dold Insulation Monitoring Relay, 1, 3 Phase, DPDT, 0 → 500V ac, DIN Rail
- Dold Thermistor Motor Protection Monitoring Relay, SPDT, DIN Rail
- Dold Voltage Monitoring Relay, 3 Phase, SPDT, DIN Rail
- Dold Insulation Monitor, SPDT, 400 → 1000V ac/dc, DIN Rail
- Dold Level Monitoring Relay, DIN Rail