Honeywell GLC Series Roller Plunger Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- RS 제품 번호:
- 308-1816
- Distrelec 제품 번호:
- 136-30-555
- 제조사 부품 번호:
- GLCB01C
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩178,951.50
일시적 품절
- 2026년 7월 29일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩178,951.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 308-1816
- Distrelec 제품 번호:
- 136-30-555
- 제조사 부품 번호:
- GLCB01C
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Plunger | |
| IP Rating | IP66 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Series | GLC | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -40°C | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | UL, CCC, CE, CSA | |
| Depth | 26.35mm | |
| Width | 30.5mm | |
| Length | 68.5mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | PG13.5 | |
| Mechanical Life | 10000000Cycles | |
| Operating Force | 16N | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Plunger | ||
IP Rating IP66 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Series GLC | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -40°C | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals UL, CCC, CE, CSA | ||
Depth 26.35mm | ||
Width 30.5mm | ||
Length 68.5mm | ||
Hazardous Area Certification No | ||
Conduit Entry PG13.5 | ||
Mechanical Life 10000000Cycles | ||
Operating Force 16N | ||
- COO (Country of Origin):
- GB

Honeywell GLC Series Limit Switch, 6A Switching Current, IP66 - GLCB01C
This limit switch provides a Compact mechanical Interface for position detection and circuit control in industrial systems. It uses a roller plunger actuator to register motion and change contact state, designed for environments where robust switching and environmental protection are required. The device is suited to control and safety tasks within automation, electrical and mechanical assemblies.
Features and Benefits:
• Snap‑action contacts deliver quick state transition and precise signalling
• 1NC/1NO contact arrangement supports dual control circuits
• Rated for 240V AC switching at 6 A enabling mains‑level loads
• Operating force of 16 N gives consistent actuation response
• IP66 enclosure prevents dust ingress and powerful water jets
• Mechanical endurance of 10,000,000 cycles ensures prolonged operational life
• 1NC/1NO contact arrangement supports dual control circuits
• Rated for 240V AC switching at 6 A enabling mains‑level loads
• Operating force of 16 N gives consistent actuation response
• IP66 enclosure prevents dust ingress and powerful water jets
• Mechanical endurance of 10,000,000 cycles ensures prolonged operational life
Applications
• Suitable for limit detection on conveyor end stops and Gates
• Ideal for actuator position sensing in industrial valves
• Used with motor starters for overtravel protection routines
• Can be used for safety interlocks on access panels
• Used for position feedback in material‑handling equipment
• Ideal for actuator position sensing in industrial valves
• Used with motor starters for overtravel protection routines
• Can be used for safety interlocks on access panels
• Used for position feedback in material‑handling equipment
What conduit entry is provided for wiring connections?
A PG13.5 conduit entry is supplied to accept compatible threaded conduit fittings and cable glands.
Which ambient temperatures can it withstand during operation?
It operates reliably between −40 °C and 85 °C, accommodating cold storage to warm machine‑room conditions.
What is the enclosure material and its protective treatment?
The body is metal with an electrostatic epoxy coating applied to provide corrosion resistance and a Durable finish.
Which certification marks indicate recognised approvals?
The unit carries UL, CCC, CE and CSA approvals indicating multiple international safety assessments.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLC Series Plunger Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- Honeywell GLC Series Plunger Limit Switch, SPDT, IP66, Die Cast Zinc Epoxy Coated Housing, 240V ac, 6A
- Honeywell GLC Series Roller Plunger Limit Switch, SPDT, IP66, Die Cast Zinc Epoxy Coated Housing, 240V ac, 6A
- Honeywell GLC Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- Honeywell GLC Series Rod Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- Honeywell GLC Series Plunger Limit Switch, 2 NC, IP66, Die Cast Zinc Epoxy Coated Housing, 600V ac, 10A
- Honeywell GLC Series Rotary Lever Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- Honeywell GLC Series Coil Spring Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A