Honeywell GLC Series Plunger Limit Switch, SPDT, IP66, Die Cast Zinc Epoxy Coated Housing, 240V ac, 6A

Subtotal (1 unit)*

₩172,926.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 5 개 단위 배송 준비 완료
  • 추가로 2026년 5월 08일 부터 25 개 단위 배송
  • 추가로 2026년 5월 25일 부터 25 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩172,926.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
308-1923
제조사 부품 번호:
GLCB07B
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Actuator Type

Plunger

Product Type

Limit Switch

Contact Configuration

SPDT

IP Rating

IP66

Housing Material

Die Cast Zinc Epoxy Coated

Contact Type

Snap Action

Terminal Type

Screw

Switching Current

6A

Series

GLC

Switching DC Voltage

250V dc

Switching AC Voltage

240V ac

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

85°C

Width

30.5mm

Length

68.5mm

Depth

26.35mm

Standards/Approvals

CCC, CE, CSA, UL

Hazardous Area Certification

No

Mechanical Life

10000000Cycles

Operating Force

16N

Conduit Entry

PG13.5

Honeywell GLC Series Limit Switch, 6A Switching Current, IP66 - GLCB07B


This limit switch is a Compact mechanical device that detects and signals the position of moving parts in industrial systems. It employs a plunger actuator and snap-action contacts to provide fast switching for control and safety circuits. The housing is constructed from die-cast zinc and the unit is engineered for use in demanding environments where ingress protection and a wide operating temperature range are required.

Features and Benefits:


• SPDT snap-action contact provides Rapid state change and clear signalling
• IP66 enclosure keeps internal components protected from dust and powerful water jets
• Operating force of 16 N ensures consistent actuation under variable loads
• Electrical switching capacity of 6A at 240V AC supports common control circuits
• Mechanical endurance rated to 10 million cycles minimises service interventions
• Conduit entry PG13.5 enables secure cable gland installation

Applications


• Suitable for limit detection on conveyor endstops and Gates
• Ideal for position feedback in automated assembly equipment
• Used with hydraulic cylinders for stroke limit monitoring
• Can be used for safety interlocks on machine guards
• Suitable for control panels in outdoor process installations

What temperature range can it tolerate in field installations?


It operates reliably from −40 °C up to 85 °C, permitting use in both cold storage and elevated-heat enclosures.

How is the device wired into an existing control circuit?


The single-pole double-throw contact provides both normally open and normally closed outputs for direct connection to control relays or PLC input modules.

What materials and approvals support industrial deployment?


The enclosure is die-cast zinc and the unit carries CCC, CE, CSA and UL recognitions for conformity to multiple regional standards.

What voltages can the switch handle for DC applications?


It is rated for switching up to 250V DC, allowing integration with common DC control supplies.

Approvals

UL/ UL listed for Canada

Warning

GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.