Fluke Networks FiberLert-125 Single & Multimode Fibre Optic Locator

Subtotal (1 unit)*

₩265,305.60

Add to Basket
수량 선택 또는 입력
제한된 재고
  • 22 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩265,305.60

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
234-8363
Distrelec 제품 번호:
302-39-035
제조사 부품 번호:
FIBERLERT-125
제조업체:
Fluke Networks
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke Networks

Product Type

Fibre Tester

Cable Type

Single & Multimode

Equipment Type

Fibre Optic Locator

Connector Type

1.25 mm LC Receptacle

Maximum Power Measurement

3dBm

Battery Type

AAA

Minimum Power Measurement

-30dBm

Wavelength

1625nm

Battery Life

1h

Power Source

Battery

Weight

59g

Standards/Approvals

No

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

50°C

Model Number

FiberLert-125

COO (Country of Origin):
GB

Fluke Fibre Tester, 1625nm Wavelength, 1h Battery Life - FIBERLERT-125


This Fibre tester is a handheld detector for Rapid verification of optical signal presence, polarity and Basic connectivity in single‑mode and multimode networks. It senses near‑infrared light in ports and patchcord end faces without contacting the ferrule, providing an immediate Visual and audible indication of Active links across telecom and industrial cabling environments.

Features & Benefits


• Detects 850 nm–1625 nm wavelengths to identify Active links quickly
• Measures optical power from −30 dBm to 3 dBm for Basic power checks
• Non‑contact ceramic ferrule to avoid endface contamination or damage
• LightBeat™ LED and audible tone to indicate operation and battery status
• Automatic shut‑off after five minutes to conserve battery life
• Supplied with AAA alkaline cells for immediate field use

Applications


• Suitable for verifying FTTH drop and distribution ports
• Ideal for polarity checks on LC patchcords in data centres
• Used for commissioning of single‑ and multimode campus links
• Can be used for fault localisation on multimode patch panels
• Used with UPC and APC connectors during site handovers

How is battery life managed for intermittent field inspections?


The unit includes a timer that powers the detector down after five minutes of inactivity and uses two AAA alkaline cells to extend operational readiness.

Which connector interfaces can be tested directly without adapters?


The detector’s non‑contact ferrule is compatible with 1.25mm LC receptacles and works with both UPC and APC terminations.

What environmental conditions will it tolerate during on‑site use?


It operates between −10 °C and 50 °C and supports non‑condensing humidity up to 95% at 10 °C–35 °C with reduced tolerance at higher temperatures.

Can it indicate power presence without Visual access to the Fibre end?


Yes

a steady red LED combined with an audible beep (when enabled) signals detected near‑infrared emissions through the non‑contact interface.