Phoenix Contact, VAL-MS 230/FM Surge Arrester 275 V ac Maximum Voltage Rating 40kA Maximum Surge Current Type 2 Arrester
- RS 제품 번호:
- 802-8138
- 제조사 부품 번호:
- 2839130
- 제조업체:
- Phoenix Contact
가격 개당**
₩192,501.40
13 <재고있음> 5-9영업일내 홍콩 발송*
* 배송 날짜는 선택한 수량과 배송 주소에 따라 달라질 수 있습니다.
수량 | 한팩당 |
---|---|
1 + | ₩192,501.40 |
**다른 단위에 대한 가격 표시
- RS 제품 번호:
- 802-8138
- 제조사 부품 번호:
- 2839130
- 제조업체:
- Phoenix Contact
해당 안됨
- COO (Country of Origin):
- DE
VALVETRAB® Pluggable single-pole modular lightning surge protector
The 2798844 from Phoenix Contact is a type 2 surge protection plug. This plug is designed to protect low voltage or three phase power supplies in your installations. It's backed with thermal monitoring, easy pluggable design thats allow for simple maintenance, mechanical indicator that shows the status and a wiring bridge that allows multiple modules to easily connect and be bridged on the ground connection. VALVETRAB provides L-N and L-PEN protection.
Features and benefits:
VALVETRAB is a mid-capacity lightning and surge protected designed to protect the low voltage single- or three-phase power supply of your installations.
With its strong surge protection, it quenches overvoltage resulting from distant impacts or resulting phenomena.
Its pluggable design allows for easy maintenance (surge protector plug combined with a base for electrical connection).
Disconnection feature provides continuity of electrical power supply.
Features a mechanical indicator which provides a status (operational or out of order) at all times and changeover contacts for alarm reports.
Connects in parallel on the mains network and snaps onto a symmetric profile.
A wiring bridge allows several modules to be quickly mounted and bridged on the ground connection.
With its strong surge protection, it quenches overvoltage resulting from distant impacts or resulting phenomena.
Its pluggable design allows for easy maintenance (surge protector plug combined with a base for electrical connection).
Disconnection feature provides continuity of electrical power supply.
Features a mechanical indicator which provides a status (operational or out of order) at all times and changeover contacts for alarm reports.
Connects in parallel on the mains network and snaps onto a symmetric profile.
A wiring bridge allows several modules to be quickly mounted and bridged on the ground connection.
Accessories:
Phoenix Contact VAL-MS 230/FM Series Surge Arrester, 275V AC Maximum Voltage Rating, DIN Rail Mount - 2839130
This surge arrester is specifically designed to protect against electrical surges in industrial settings. With a maximum voltage rating of 275V AC, it effectively safeguards sensitive electronic equipment. Its Type 2 classification makes it crucial in surge protection systems, suitable for environments prone to high surge currents.
Features & Benefits
• Compact design for DIN rail mounting
• Handles maximum surge currents up to 40kA
• Functions in temperatures ranging from -40 to +80°C
• Provides high surge current protection for devices
• Handles maximum surge currents up to 40kA
• Functions in temperatures ranging from -40 to +80°C
• Provides high surge current protection for devices
Applications
• Safeguarding electrical equipment against surges
• Ideal for installation in control cabinets and distribution boards
• Protecting sensitive electronic
• Ideal for installation in control cabinets and distribution boards
• Protecting sensitive electronic
What installation requirements are needed for proper functionality?
Ensure the unit is securely mounted on a DIN rail and properly connected to the supply circuit for optimal performance.
How does it perform in extreme temperatures?
The device operates effectively across a wide temperature range, maintaining functionality in both low and high temperature extremes.
Is it compatible with other surge protection devices?
Yes, it can integrate with various types of surge protection systems to enhance overall electrical safety.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
속성 | 값 |
---|---|
Suppressor Type | Type 2 Arrester |
Maximum Voltage Rating | 275 V ac |
Mounting Type | DIN Rail |
Maximum Surge Current | 40kA |
Series | VAL-MS 230/FM |
Length | 17.7mm |
Depth | 65.7mm |
Height | 96.8mm |
Dimensions | 96.8 x 17.6 x 65.7mm |
Minimum Operating Temperature | -40°C |
Maximum Operating Temperature | +80°C |