Schneider Electric XPSU, 240V ac/dc, 48 V ac/dc Safety Relay, 2 Safety Contacts, 2

Subtotal (1 unit)*

₩761,920.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 11 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩761,920.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
200-6142
제조사 부품 번호:
XPSUS32AC
제조업체:
Schneider Electric
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Schneider Electric

Product Type

Safety Relay

Safety Contacts

2

Contact Configuration

2 NC

Number of Auxiliary Contacts

2

Reset Method

Automatic and Manual and Monitored

Mount Type

DIN Rail

Power Consumption

8.5VA

Series

XPSU

Terminal Type

Spring Terminal

IP Rating

IP20, IP40, IP54

Standards/Approvals

IEC 62061 functional safety standard, IEC 61508-6 functional safety standard, IEC 60947-5-1, cULus, IEC 61508-5 functional safety standard, IEC 61508-1 functional safety standard, IEC 61508-4 functional safety standard, IEC 61508-7 functional safety standard, TÜV, IEC 61508-3 functional safety standard, ISO 13849-1 functional safety standard, IEC 61508-2 functional safety standard

Switching DC Voltage

250V dc

Switching AC Voltage

250V ac

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Length

100mm

Height

120mm

Width

22.5mm

Hazardous Area Certification

No

Safety Category

PLe/Category 4 EN ISO 13849-1

Coil Voltage

240V ac/dc, 48V ac/dc

COO (Country of Origin):
ID

Schneider Electric Preventa Range of Safety Relays - XPS Universal Range


These safety relays and brought to you with a clever design that allows the monitoring of dangerous operations. To initiate a dangerous movement both operators must be activated within an interval of 0.5 seconds which is referred to as synchronous activation. If one of the two pushbuttons are released during a dangerous operation, the control sequence is automatically cancelled. Users can resume the dangerous operation through both pushbuttons returning to their initial position and reactivating them within the required time interval. The XPSUS range of safety modules have been created and designed to monitor:

• Emergency stops

• Guard switches

• Magnetic switches

• Proximity safety switches

• PNP sensors

• RFID safety switches

• Safety light curtains

• Two handed control stations

• Enabling switches

Features & Benefits


• Automatic, manual and monitored start

• 2 safety inputs

• 3 ON/OFF configurable pulsed outputs

• 2 NO safety outputs

• 1 solid-state diagnostic output with complete status information

• Removable terminal blocks as the connection type

Schneider Electric Preventa Safety Module - XPSUS32AC


• Forms part of the Preventa Safety automation range of products

• Features a safety level of Can reach PL e/category 4 conforming to ISO 13849-1, Can reach SILCL 3 conforming to IEC 62061 and Can reach SIL 3 conforming to IEC 61508

• The electrical circuit types are NC pair, PNP pair, Antivalent pair and OSSD pair

• Has a supply voltage of 48...240 V AC/DC - 10...10 %

• Internal and electronic input protection type

• Magnetic switch monitoring

• RFID switch