SICK RE21 Safety Switch Actuator Included, Vistal, Magnet

Subtotal (1 unit)*

₩138,500.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 3 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩138,500.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-2281
제조사 부품 번호:
RE21-SA84
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Safety Switch

Lock Type

Magnet

Actuator Included

Yes

Safety Contacts

1 NO/1 NC

Housing Material

Vistal

Series

RE21

IP Rating

IP67

Switch Contact Current

400mA

Contact DC Voltage

30V dc

Minimum Operating Temperature

-30°C

Contact AC Voltage

230V ac

Maximum Operating Temperature

60°C

Hazardous Area Certification

No

Width

13mm

Number of Head Directions

5

Depth

25mm

Standards/Approvals

IEC 60529

Length

88mm

COO (Country of Origin):
DE

SICK RE21 Series Safety Switch, IP67, 1NO 1NC Safety Contacts - RE21-SA84


This safety switch is a non-contact magnetic sensor designed to monitor guard positions in industrial environments. It operates with reed outputs and connects via a short cable with an M8 4-pin male connector, offering status indication through LEDs. The unit is housed in VISTAL® material and is intended for use where a compact, sealed interlock is required while the safety logic is handled by external circuitry.

Features and Benefits:


• IP67 enclosure protects against dust and water ingress
• 400mA contact current supports low-power safety circuits
• Switchable up to 230V AC for AC safety monitoring
• Operates between -30 to 60°C for broad ambient conditions
• Five actuation directions enable flexible mounting orientations

Applications


• Suitable for guarding on assembly-line access panels
• Ideal for integration with external safety logic units
• Used with metal actuators where magnetic sensing is required
• Can be used for machine perimeter interlocking in wet areas
• Used for monitoring removable covers on conveyor systems

What type of output does it provide?


It uses reed switch outputs providing one normally open and one normally closed contact for safety signalling.

How is the unit connected to a control system?


It connects via a 0.2m cable terminating in an M8 4-pin male connector with copper conductors.

Does the switch detect its own internal faults?


It has no internal fault detection

connected safety logic must perform fault monitoring.

What mechanical stresses can it withstand?


It meets vibration resistance of 10Hz to 55Hz with 1mm amplitude and shock resistance of 30g for 11ms.

관련된 링크들