Honeywell Technologies HSCMRRN100MD2A3 Differential Pressure SensorBoard SMT

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

대량 구매 할인 받기

13개 더 담고 ₩28,340.00 할인 받기

View bulk pricing options

Subtotal (1 unit)*

₩99,740.00

Add to Basket
수량 선택 또는 입력
단종되는 중
  • 최종적인 46 개 unit(s)이 배송 준비 됨

수량
한팩당
절감
1 - 12₩99,740.00-
13 - 24₩97,560.00₩28,340.00
25 +₩95,460.00₩107,000.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

포장 옵션
RS 제품 번호:
211-9933
제조사 부품 번호:
HSCMRRN100MD2A3
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Sensor Type

Differential Pressure Sensor

Product Type

Differential Pressure Sensor

Mount Type

Board

Package Type

SMT

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

10 kPa

Accuracy

±0.25 %

Maximum Supply Voltage

5V

Port Type

Dual Radial Barbed

Maximum Operating Temperature

85°C

Series

HSC

Height

13.75mm

Width

13.3mm

Standards/Approvals

ISO 9001

Length

10mm

Minimum Operating Pressure

100mbar

Automotive Standard

ISO 9001

Minimum Operating Temperature

-20°C

Honeywell HSC Series Differential Pressure Sensor, 100m bar Minimum Operating Pressure, 10kPa Maximum Operating Pressure - HSCMRRN100MD2A3


This differential pressure sensor provides low-voltage measurement of pressure differences for board-mounted systems. It is designed for surface-mount assembly with dual radial barbed ports and operates across a modest pressure range while remaining suitable for environments requiring a Compact electronic pressure transducer.

Features and Benefits:


• ±0.25% accuracy delivers precise differential readings
• Operates from 3.3 V to 5 V for flexible power options
• Dual radial barbed ports enable simple tubing connections
• SMT board mount reduces assembly time and footprint
• Rated to 85 °C supports elevated temperature operation

Applications


• Suitable for HVAC airflow monitoring and control
• Ideal for medical device flow differential measurement
• Used with Compact pneumatic manifolds in laboratory equipment
• Can be used for industrial filter clog detection
• Suitable for automotive-related sensor integration tasks

What supply voltage range can it accept?


It functions with a minimum supply of 3.3 V and a maximum of 5 V.

What pressure span is measurable with this device?


It measures differential pressures from 100 mbar up to 10 kPa.

How accurate are the pressure measurements?


Measurement accuracy is ±0.25% relative to the reading.

What mounting and port configurations are provided?


The device is supplied for surface-mount board attachment and includes two radial barbed ports for tubing.

What temperature range can it reliably operate within?


The operating temperature range extends from -20 °C up to 85 °C.