Honeywell Technologies HSCMRRN060PDSA3 Differential Pressure SensorSurface 8 SMT

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

대량 구매 할인 기용 가능
View bulk pricing options

Subtotal (1 Box of 50 units)*

₩6,519,300.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 12월 09일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.

수량
한팩당
Per Box*
50 - 200₩130,386.00₩6,519,260.00
250 +₩127,778.00₩6,388,880.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
214-1468
제조사 부품 번호:
HSCMRRN060PDSA3
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Sensor Type

Piezoresistive Pressure Sensor

Product Type

Differential Pressure Sensor

Maximum Overload Pressure

250psi

Mount Type

Surface

Package Type

SMT

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

60 psi

Maximum Supply Voltage

5V

Port Type

Dual Radial Barbed

Accuracy

±0.25 %

Maximum Operating Temperature

85°C

Height

13.75mm

Series

HSC

Width

13.3mm

Length

10mm

Standards/Approvals

No

Maximum Output Voltage

6V

Minimum Operating Pressure

-60psi

Minimum Operating Temperature

-20°C

Minimum Output Voltage

-0.30V

Automotive Standard

No

Honeywell HSC Series Differential Pressure Sensor, ±0.25% Accuracy -60 to 60psi Operating Pressure - HSCMRRN060PDSA3


This differential pressure sensor converts small pressure differentials into an electrical output for low-voltage systems. It operates across a bidirectional range suited to HVAC and instrumentation tasks, tolerates elevated overloads, and is intended for printed-circuit mounting in Compact assemblies. The device provides a measurable voltage output compatible with common control electronics and functions over a moderate temperature window for many industrial environments.

Features and Benefits:


• ±0.25% accuracy delivers precise readings for control loops
• -60 to 60 psi operating range supports bidirectional measurement
• 3.3 to 5V supply enables low-voltage electronic integration
• 250 psi overload protection prevents damage from pressure spikes
• Dual radial barbed ports allow straightforward tubing connections

Applications


• Suitable for airflow monitoring in HVAC systems
• Ideal for differential filter-clog detection
• Used with low-voltage controllers in building automation
• Can be used for lab-scale pressure comparison setups
• Suitable for OEM devices requiring Compact sensing elements

What electrical output range can I expect from the device?


The sensor provides an output voltage that spans from -0.30V up to 6V corresponding to measured differential pressures.

How is the sensor intended to be mounted on a circuit?


It is supplied in an SMT package with surface-mount configuration and eight electrical connections for PCB integration.

What environmental limits apply to its operation?


Operational temperature limits extend from -20°C to 85°C and it functions reliably within that range.

How many pressure ports are provided and what form do they take?


Two radial barbed ports are fitted to accept tubing for differential pressure connection.

What is the maximum permitted supply voltage for this device?


The maximum supply voltage specified for operation is 5V.