Omron Panel Power Relay, 120V ac Coil, 25A Switching Current, 4PST-NO

본 이미지는 참조용이오니 재확인이 필요하시면 문의해주세요.

Subtotal (1 unit)*

₩67,660.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2026년 11월 09일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩67,660.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

포장 옵션
RS 제품 번호:
684-0113
제조사 부품 번호:
G7J-4A-T 100/120VAC
제조업체:
Omron
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Omron

Coil Voltage

120V ac

Product Type

Power Relay

Contact Configuration

4PST-NO

Mount Type

Panel

Series

G7J

Terminal Type

Tab Terminal

Switching Current

25A

Switching AC Voltage

250V ac

Switching DC Voltage

125V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

60°C

Width

34.5mm

Standards/Approvals

UL, CSA

Length

51.5mm

Coil Power

2.6VA

Height

64mm

Contact Material

Silver Alloy

Contact Resistance

100mΩ

COO (Country of Origin):
JP

Omron G7J Series Power Relay, 120V Coil Voltage, 25A Switching Current - G7J-4A-T 100/120VAC


This power relay is a Compact electromechanical switching device designed for control and automation panels, providing reliable circuit switching in industrial environments. It is intended for applications requiring a moderate Coil input and high-contact switching capability, suitable where a tab-terminal mounting and a W‑bracket fitment are preferred.

Features and Benefits:


• 120V AC Coil rated at 2.6VA for predictable Coil consumption
• Four single-pole contacts enabling simultaneous switching of multiple circuits
• Silver-alloy contact faces to reduce contact wear and improve conductivity
• Switching capability of 25A for handling substantial load currents
• Can switch AC up to 250V and DC up to 125V for versatile load types

Applications


• Suitable for motor control contact switching in automation panels
• Ideal for interfacing control logic with high-current loads
• Used for switching heater circuits in industrial equipment
• Can be used for load transfer in power distribution modules

What Terminal and mounting methods are used for installation?


Connections are provided via straight tab terminals while the relay body is secured using a W‑bracket mount to suit panel assemblies.

How does the relay perform across temperature ranges?


It operates over an ambient span from −25°C up to a maximum of 60°C, allowing use in typical industrial indoor environments.

What approvals cover its safety and regulatory acceptance?


It carries underwriter and certification approvals recognised in North America, indicated by UL and CSA listings.

What is the electrical contact resistance and how does it affect performance?


Contact resistance is specified at 100 mΩ, minimising voltage drop across closed contacts for efficient current transfer.