PicoScope 6000E Series, 1 GHz PC Based Oscilloscope 4-Channel

Subtotal (1 unit)*

₩24,507,400.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 1 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩24,507,400.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
222-2084
제조사 부품 번호:
PicoScope 6406E
제조업체:
Pico Technology
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Pico Technology

Product Type

Oscilloscope

Bandwidth

1GHz

Number of Channels

4

Model Number

PicoScope 6406E

Oscilloscope Type

PC Based

Interface Type

USB

Series

PicoScope 6000E

Height

61.50mm

Length

245mm

Standards/Approvals

EN 61010, EN 613261:2013, REACH, RoHS, WEEE

Width

192mm

Maximum Vertical Sensitivity

4V/div

Minimum Vertical Sensitivity

2mV/div

Minimum Time Base

1ns/div

Rise Time

850ps

Maximum Time Base

5000s/div

Power Source

USB

Vertical Resolution

8 bit

COO (Country of Origin):
GB

PicoScope 6000E Series Oscilloscope, 1 GHz Bandwidth, 4 Channels - PicoScope 6406E


This oscilloscope is a PC‑connected instrument that captures and displays electrical signals for analysis. It is powered and interfaced via USB and operates as a compact, USB‑driven solution suitable for laboratory and workshop environments. The instrument supports Rapid signal acquisition across four inputs and complies with relevant European safety and environmental standards.

Features and Benefits:


• 1 ns/div minimum time base enables observation of fast time‑domain events
• 1GHz bandwidth delivers high‑frequency signal fidelity
• 850 ps rise time resolves fast edge transitions
• 8‑bit vertical resolution provides clear amplitude representation
• 2 mV/div minimum sensitivity detects low‑level signals

Applications


• Suitable for high‑speed digital signal analysis tasks
• Ideal for multi‑channel transient capture on test benches
• Used for USB‑powered field measurements and diagnostics
• Can be used for educational laboratory waveform demonstrations

How is the instrument powered during use?


It receives power through the USB connection, eliminating separate power supplies.

What safety and environmental standards does it meet?


The unit conforms to EN 61010, EN 61326‑1:2013, REACH, RoHS and WEEE requirements.

What vertical input range can I expect for amplitude measurements?


The instrument supports vertical sensitivities from 2 mV/div up to 4 V/div to cover low to moderate amplitudes.

What physical form factor should I plan for on a test bench?


The enclosure measures 61.50 mm high by 245 mm long by 192 mm wide for Compact placement.

관련된 링크들