Fluke 705 Loop Calibrator Battery 30V

Subtotal (1 unit)*

₩2,288,793.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 7월 20일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩2,288,793.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
325-4777
Distrelec 제품 번호:
176-80-408
제조사 부품 번호:
0665091
제조업체:
Fluke
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Fluke

Product Type

Loop Calibrator

Accuracy

± 0.02 %

Model Number

705

Resolution

0.001 mA

Battery Type

AAA

Battery Life

18h

Power Source

Battery

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Standards/Approvals

CSA C22.2 No. 1010.1:1992

Length

47mm

Width

75mm

Height

164mm

Weight

340g

Hazardous Area Certification

No

Safety Category Voltage

30V

COO (Country of Origin):
CN

Fluke Loop Calibrator, 0.02% Accuracy, 0.001 mA Resolution - 0665091


This loop calibrator is a compact, handheld instrument for diagnosing and servicing current loops and voltage signals in industrial process control. Designed for field use, it measures and sources mA and volt signals, supplies loop power while monitoring current, and operates across a typical workshop temperature range for automation and maintenance tasks.

Features & Benefits


• 0.02% accuracy provides precise calibration for critical loops
• 0.001mA resolution enables fine measurement and sourcing adjustments
• 24V loop supply while measuring mA supports live loop checks
• Simultaneous mA and percentage display simplifies span verification
• Selectable step and ramp outputs assist automated response testing
• Battery operation using AAA cells delivers portable field use

**Applications**


• Suitable for commissioning and troubleshooting 4 to 20 mA transmitter loops
• Ideal for maintenance checks on PLC analogue outputs and inputs
• Used for calibration in control cabinets and on-site process diagnostics
• Can be used for verifying loop power and HART Interface resistances

How long will it run during typical field work?


Typical battery life is 18 h when sourcing at 12mA using AAA cells.

What environmental limits should be observed during operation?


Use within -10 to 55 °C and at altitudes up to 3000m with specified humidity limits.

Which safety and electromagnetic standards apply to this unit?


It meets CSA C22.2 No.1010.1 and EMC standards for industrial environments.

What measurement ranges are available for current and voltage?


Current measurement and sourcing cover 0mA to 24mA with sourcing modes 0mA–20mA or 4mA–20mA while voltage checks extend to 28V DC.

Supplied with

9V installed alkaline battery, AC70A alligator clips, C10 protective yellow holster Flex-Stand™, instruction sheet, TL75 safety-designed test lead set, NIST- traceable calibration report and data

관련된 링크들