Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- RS 제품 번호:
- 808-3163
- 제조사 부품 번호:
- GLDA01A1B
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩124,117.50
재고있음
- 16 개 단위 배송 준비 완료
- 추가로 2026년 6월 09일 부터 105 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩124,117.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 808-3163
- 제조사 부품 번호:
- GLDA01A1B
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| Contact Configuration | SPDT | |
| IP Rating | IP66 | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Snap Action | |
| Terminal Type | Screw | |
| Switching Current | 10A | |
| Series | GLD | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Depth | 26.35mm | |
| Length | 68.5mm | |
| Width | 30.5mm | |
| Standards/Approvals | EN, UL, RoHS, IEC, CSA, CE, CCC | |
| Hazardous Area Certification | No | |
| Conduit Entry | 1/2 in to 14 NPT | |
| Mechanical Life | 10000000Cycles | |
| Operating Force | 0.12Nm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
Contact Configuration SPDT | ||
IP Rating IP66 | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Snap Action | ||
Terminal Type Screw | ||
Switching Current 10A | ||
Series GLD | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Depth 26.35mm | ||
Length 68.5mm | ||
Width 30.5mm | ||
Standards/Approvals EN, UL, RoHS, IEC, CSA, CE, CCC | ||
Hazardous Area Certification No | ||
Conduit Entry 1/2 in to 14 NPT | ||
Mechanical Life 10000000Cycles | ||
Operating Force 0.12Nm | ||
Honeywell GLD Series Limit Switch, Roller Lever Actuator, IP66 - GLDA01A1B
This limit switch provides a compact, industrial-grade mechanical position sensing solution for automation and control systems. It employs a roller lever actuator to detect motion and transmit a discrete switching signal, designed for use in demanding environments where robust enclosure protection and defined switching behaviour are required.
Features and Benefits:
• SPDT snap-action contact offers clear single-pole changeover switching
• Rated for 10A enables handling of significant control currents
• IP66 fibreglass-reinforced enclosure resists dust and powerful jets
• Mechanical endurance of 10 million cycles supports long service intervals
• Operating range from −40 °C to 85 °C suits extreme temperature conditions
• Actuation force 16 N provides predictable trigger response under load
• Rated for 10A enables handling of significant control currents
• IP66 fibreglass-reinforced enclosure resists dust and powerful jets
• Mechanical endurance of 10 million cycles supports long service intervals
• Operating range from −40 °C to 85 °C suits extreme temperature conditions
• Actuation force 16 N provides predictable trigger response under load
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for safety interlocks on industrial guarding systems
• Used with motor starters for position feedback in hoists and lifts
• Can be used for limit detection on automation pick-and-place units
• Used for end-stop sensing in material handling equipment
• Ideal for safety interlocks on industrial guarding systems
• Used with motor starters for position feedback in hoists and lifts
• Can be used for limit detection on automation pick-and-place units
• Used for end-stop sensing in material handling equipment
What conduit entry options are available for cable installation?
The unit accepts a 1/2 in to 14 NPT conduit entry for standard threaded conduit connections.
How does the contact arrangement affect wiring flexibility?
The single-pole double-throw configuration allows selection between normally closed and normally open circuits for flexible control logic.
What voltages can the contacts switch for AC and DC loads?
The contacts are specified for switching at 240V AC and up to 250V DC to accommodate typical control and signal voltages.
What material is the housing and how does it influence durability?
The enclosure is MADE from fibreglass-reinforced thermoplastic, providing mechanical resilience and corrosion resistance in harsh settings.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V
- Honeywell GLD Series Rod Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing,
- Honeywell GLD Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac,
- Honeywell GLD Series Plunger Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A