Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A

Subtotal (1 unit)*

₩124,117.50

Add to Basket
수량 선택 또는 입력
재고있음
  • 16 개 단위 배송 준비 완료
  • 추가로 2026년 6월 09일 부터 105 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩124,117.50

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
808-3163
제조사 부품 번호:
GLDA01A1B
제조업체:
Honeywell
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Honeywell

Actuator Type

Roller Lever

Product Type

Limit Switch

Contact Configuration

SPDT

IP Rating

IP66

Housing Material

Fibreglass Reinforced Thermoplastic

Contact Type

Snap Action

Terminal Type

Screw

Switching Current

10A

Series

GLD

Switching DC Voltage

250V dc

Switching AC Voltage

240V ac

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

85°C

Depth

26.35mm

Length

68.5mm

Width

30.5mm

Standards/Approvals

EN, UL, RoHS, IEC, CSA, CE, CCC

Hazardous Area Certification

No

Conduit Entry

1/2 in to 14 NPT

Mechanical Life

10000000Cycles

Operating Force

0.12Nm

Honeywell GLD Series Limit Switch, Roller Lever Actuator, IP66 - GLDA01A1B


This limit switch provides a compact, industrial-grade mechanical position sensing solution for automation and control systems. It employs a roller lever actuator to detect motion and transmit a discrete switching signal, designed for use in demanding environments where robust enclosure protection and defined switching behaviour are required.

Features and Benefits:


• SPDT snap-action contact offers clear single-pole changeover switching
• Rated for 10A enables handling of significant control currents
• IP66 fibreglass-reinforced enclosure resists dust and powerful jets
• Mechanical endurance of 10 million cycles supports long service intervals
• Operating range from −40 °C to 85 °C suits extreme temperature conditions
• Actuation force 16 N provides predictable trigger response under load

Applications


• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for safety interlocks on industrial guarding systems
• Used with motor starters for position feedback in hoists and lifts
• Can be used for limit detection on automation pick-and-place units
• Used for end-stop sensing in material handling equipment

What conduit entry options are available for cable installation?


The unit accepts a 1/2 in to 14 NPT conduit entry for standard threaded conduit connections.

How does the contact arrangement affect wiring flexibility?


The single-pole double-throw configuration allows selection between normally closed and normally open circuits for flexible control logic.

What voltages can the contacts switch for AC and DC loads?


The contacts are specified for switching at 240V AC and up to 250V DC to accommodate typical control and signal voltages.

What material is the housing and how does it influence durability?


The enclosure is MADE from fibreglass-reinforced thermoplastic, providing mechanical resilience and corrosion resistance in harsh settings.

Approvals

UL/ UL listed for Canada

Warning

GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.

관련된 링크들