Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- RS 제품 번호:
- 808-3160
- 제조사 부품 번호:
- GLDA01A1A
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩220,603.50
일시적 품절
- 2026년 7월 06일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩220,603.50 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 808-3160
- 제조사 부품 번호:
- GLDA01A1A
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| IP Rating | IP66 | |
| Contact Configuration | SPDT | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Snap Action | |
| Terminal Type | Screw | |
| Switching Current | 10A | |
| Series | GLD | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | RoHS, IEC, EN, CSA, CE, CCC, UL | |
| Length | 68.5mm | |
| Width | 30.5mm | |
| Depth | 26.35mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.12Nm | |
| Mechanical Life | 10000000Cycles | |
| Conduit Entry | 1/2 in to 14 NPT | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
IP Rating IP66 | ||
Contact Configuration SPDT | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Snap Action | ||
Terminal Type Screw | ||
Switching Current 10A | ||
Series GLD | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals RoHS, IEC, EN, CSA, CE, CCC, UL | ||
Length 68.5mm | ||
Width 30.5mm | ||
Depth 26.35mm | ||
Hazardous Area Certification No | ||
Operating Force 0.12Nm | ||
Mechanical Life 10000000Cycles | ||
Conduit Entry 1/2 in to 14 NPT | ||
Honeywell GLD Series Limit Switch, Roller Lever Actuator, IP66 - GLDA01A1A
This limit switch provides a compact, industrial-grade means of detecting mechanical position changes and initiating control actions in automation and machinery contexts. It is designed for robust use where a roller‑lever actuator and snap‑action contacts are required to convert mechanical motion into a reliable electrical signal.
Features and Benefits:
• SPDT snap‑action contacts switching up to 10A provide clear on/off signalling
• Roller lever actuator delivers precise mechanical actuation with 16N force
• Fibreglass‑reinforced thermoplastic enclosure ensures chemical and impact resistance
• Wide operating temperature range from -40°C to 85°C enables harsh‑environment operation
• Mechanical endurance rated to 10 million cycles reduces maintenance frequency
• IP66 ingress protection allows use in dusty and high‑pressure washdown areas
• Roller lever actuator delivers precise mechanical actuation with 16N force
• Fibreglass‑reinforced thermoplastic enclosure ensures chemical and impact resistance
• Wide operating temperature range from -40°C to 85°C enables harsh‑environment operation
• Mechanical endurance rated to 10 million cycles reduces maintenance frequency
• IP66 ingress protection allows use in dusty and high‑pressure washdown areas
Applications
• Suitable for end‑of‑travel sensing on conveyor line equipment
• Ideal for position feedback on industrial presses and stamping machines
• Used with automated Gates and safety interlocks in production cells
• Can be used for limit detection on packaging and material‑handling systems
• Ideal for position feedback on industrial presses and stamping machines
• Used with automated Gates and safety interlocks in production cells
• Can be used for limit detection on packaging and material‑handling systems
What electrical switching capability does it offer for control circuits?
The device uses single‑pole double‑throw contacts capable of handling AC loads to 240V and DC loads to 250V with a maximum current of 10A.
How is conduit connection handled for wiring runs?
It accepts a 1/2 in to 14 NPT conduit entry to integrate into standard industrial conduit systems.
What approvals support use in regulated installations?
Certification includes multiple international standards covering safety and performance such as IEC and recognised national test marks.
How small is the unit for tight‑space mounting?
The housing is Compact with a length of 68.5mm, a width of 30.5mm and a depth of 26.35mm to facilitate installation where space is constrained.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V
- Honeywell GLD Series Rod Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing,
- Honeywell GLD Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac,
- Honeywell GLD Series Plunger Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A