Honeywell GLD Series Metal Roller Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- RS 제품 번호:
- 311-2279
- 제조사 부품 번호:
- GLDB06A1B
- 제조업체:
- Honeywell
Subtotal (1 unit)*
₩129,360.00
재고있음
- 40 개 단위 배송 준비 완료
- 추가로 2026년 10월 19일 부터 25 개 단위 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량 | 한팩당 |
|---|---|
| 1 + | ₩129,360.00 |
* 참고 가격: 실제 구매가격과 다를 수 있습니다
- RS 제품 번호:
- 311-2279
- 제조사 부품 번호:
- GLDB06A1B
- 제조업체:
- Honeywell
사양
참조 문서
제정법과 컴플라이언스
제품 세부 사항
제품 정보를 선택해 유사 제품을 찾기
모두 선택 | 제품 정보 | 값 |
|---|---|---|
| 브랜드 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Metal Roller | |
| IP Rating | IP66 | |
| Contact Configuration | DPST | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Slow Action | |
| Terminal Type | Screw | |
| Switching Current | 6A | |
| Series | GLD | |
| Switching AC Voltage | 240V ac | |
| Minimum Operating Temperature | -40°C | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | CSA, CE, UL, CCC | |
| Depth | 26.35mm | |
| Length | 68.5mm | |
| Width | 30.5mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 10000000Cycles | |
| Conduit Entry | PG13.5 | |
| Operating Force | 0.11Nm | |
| 모두 선택 | ||
|---|---|---|
브랜드 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Metal Roller | ||
IP Rating IP66 | ||
Contact Configuration DPST | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Slow Action | ||
Terminal Type Screw | ||
Switching Current 6A | ||
Series GLD | ||
Switching AC Voltage 240V ac | ||
Minimum Operating Temperature -40°C | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals CSA, CE, UL, CCC | ||
Depth 26.35mm | ||
Length 68.5mm | ||
Width 30.5mm | ||
Hazardous Area Certification No | ||
Mechanical Life 10000000Cycles | ||
Conduit Entry PG13.5 | ||
Operating Force 0.11Nm | ||
- COO (Country of Origin):
- GB

Honeywell GLD Series Limit Switch, Metal Roller Actuator, IP66 - GLDB06A1B
This limit switch is a Compact mechanical position sensor designed for industrial automation and control systems. It detects actuations via a metal roller actuator and is intended for installation in harsh environments where a sealed enclosure and reliable switching are required. The device connects to control circuitry via screw terminals and accepts a standard PG13.5 conduit entry for wiring.
Features and Benefits:
• Metal roller actuator reduces wear and enables consistent actuation force
• DPST slow-action contacts provide controlled switching behaviour under load
• Rated switching current 6A to handle moderate control circuits
• Operational temperature range -40 to 85 °C for wide thermal conditions
• Fibreglass-reinforced thermoplastic housing delivers impact and corrosion resistance
• Mechanical endurance rated to 10 000 000 cycles for long service intervals
• DPST slow-action contacts provide controlled switching behaviour under load
• Rated switching current 6A to handle moderate control circuits
• Operational temperature range -40 to 85 °C for wide thermal conditions
• Fibreglass-reinforced thermoplastic housing delivers impact and corrosion resistance
• Mechanical endurance rated to 10 000 000 cycles for long service intervals
Applications
• Suitable for end-of-travel detection on conveyor equipment
• Ideal for limit sensing on industrial valves and actuators
• Used with motor starters for safety interlock switching
• Can be used for position feedback in packaging machinery
• Used for control panel input via PG13.5 conduit installations
• Ideal for limit sensing on industrial valves and actuators
• Used with motor starters for safety interlock switching
• Can be used for position feedback in packaging machinery
• Used for control panel input via PG13.5 conduit installations
What approvals does the device carry for integration in electrical systems?
It holds internationally recognised approvals from CSA, CE, UL and CCC, enabling use where those standards are required.
How is the unit mounted and wired in a control panel?
The enclosure provides a PG13.5 conduit entry for cable glands and internal screw terminals for secure conductor connection.
What electrical voltages can the contacts switch for AC and DC circuits?
The contacts are specified for switching up to 240V AC at rated current and up to 250V DC for DC loads.
How does the construction support ingress protection in harsh environments?
The housing material and sealing achieve an IP66 rating, offering protection against dust ingress and powerful water jets.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
관련된 링크들
- Honeywell GLD Series Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V
- Honeywell GLD Series Roller Plunger Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- Honeywell GLD Series Plunger Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing,
- Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- Honeywell GLD Series Roller Plunger Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac,
- Honeywell GLD Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac,