Omron D4n Series Rod Limit Switch, 2 NC, IP67, Plastic Housing, 240V ac, 2.5A

Subtotal (1 unit)*

₩100,560.00

Add to Basket
수량 선택 또는 입력
일시적 품절
  • 2027년 3월 22일 부터 배송
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩100,560.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
288-3215
제조사 부품 번호:
D4N-4287
제조업체:
Omron
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Omron

Actuator Type

Rod

Product Type

Limit Switch

Contact Configuration

2 NC

IP Rating

IP67

Housing Material

Plastic

Contact Type

2 NC

Terminal Type

Terminal Block

Switching Current

2.5A

Series

D4n

Switching AC Voltage

240V ac

Switching DC Voltage

250V dc

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

+70°C

Standards/Approvals

CE, cULus

Hazardous Area Certification

No

Mechanical Life

15000000Cycles

제외

COO (Country of Origin):
JP

Omron D4n Series Limit Switch, IP67, 15000000 cycles Mechanical Life - D4N-4287


This limit switch is a mechanical actuator device designed to detect position changes and interrupt circuits in industrial settings. It uses a rod-style actuator housed in a plastic enclosure with protection against dust and water ingress, and it operates across a wide ambient temperature range for use in varied environments.

Features and Benefits:


• Rod actuator provides precise mechanical position detection
• IP67 protection enables use in wet or dusty locations
• Two normally closed contacts offer straightforward fail-safe wiring
• Switching capability supports 250VDC and 240VAC circuits
• 2.5A switching current suits modest control and signalling loads
• Mechanical endurance rated for 15,000,000 cycles reduces maintenance

Applications


• Suitable for conveyor end-of-travel sensing in factories
• Used with automated doors for travel limit control
• Ideal for packaging machines requiring position feedback
• Can be used for safety interlocks on laboratory equipment
• Used for simple PLC input signalling in control panels

What connection method does it use for wiring?


It employs a terminal-block arrangement for secure field wiring.

How does the contact arrangement affect circuit design?


The pair of normally closed contacts allows series wiring for safety circuits and straightforward monitoring of open conditions.

What environmental temperatures can it tolerate during operation?


It is specified to function between -30°C and +70°C for ambient conditions.

What approvals cover its conformity to safety standards?


It holds CE and cULus approvals indicating compliance with relevant European and North American requirements.