SICK C40S Series Light Curtain Sender, 30 mm Resolution

Subtotal (1 unit)*

₩3,523,300.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 01일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩3,523,300.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-0977
제조사 부품 번호:
C40S-0903CA010
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C40S

Beam Resolution

30mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

21m

Length

48mm

Width

40mm

Height

1.03m

COO (Country of Origin):
DE

SICK C40S Series Light Curtain, 900mm Protective Height, 24V Supply Voltage - C40S-0903CA010


This light curtain is a safety sensor designed for industrial environments to monitor access points and stop hazardous machine movements. It operates as the sender unit within an optically synchronised pair and is intended for integration into safety circuits where a Type 4 safety light curtain is required. The module supports configurable scanning ranges and communicates with compatible safety relays for controlled enabling and deactivation of outputs.

Features and Benefits:


• 30mm beam resolution for precise object detection
• 21m maximum scanning distance for long-range protection
• Type 4 safety level delivering high fault-tolerant operation
• 24V supply voltage enabling standard industrial power integration
• Compact 40mm width light curtain module for tight installations

Applications


• Suitable for safeguarding access to automated assembly lines
• Ideal for perimeter protection in material handling systems
• Used with safety relays for machine enabling and interlock functions
• Can be used for palletiser protection in packaging plants

What environmental conditions can it withstand?


It is rated to operate between 0°C and +55°C and is protected to IP65 against dust and water ingress.

How is synchronisation between sender and receiver achieved?


Synchronisation is optical, ensuring coordinated beam timing between units for correct detection.

What safety performance classifications apply to the unit?


It meets SIL3, Category 4 and PLe safety standards according to relevant IEC and ISO tests.

What electrical connection options are provided for installation?


The device uses a straight cable connection with conductor cross-section 0.75mm² and supports cable lengths up to 50m depending on load and supply.