SICK C40S Series Light Curtain Sender, 40 mm Resolution

Subtotal (1 unit)*

₩3,543,920.00

Add to Basket
수량 선택 또는 입력
제조사가 재고 비축중
  • 2026년 12월 11일 부터 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩3,543,920.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
285-0980
제조사 부품 번호:
C40S-1204CA010
제조업체:
SICK
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

SICK

Product Type

Light Curtain

Series

C40S

Beam Resolution

40mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

1.2m

Maximum Supply Voltage

24V

Maximum Scanning Distance

21m

Length

48mm

Height

1.329m

Width

40mm

COO (Country of Origin):
DE

SICK C40S Series Light Curtain, 1200mm Protective Height, 24V Supply Voltage - C40S-1204CA010


This light curtain sender unit provides safety detection for industrial environments by creating a protective sensing field to guard access to hazardous machinery. Designed for normal industrial use, it operates with optical synchronisation and delivers a configurable scanning range for flexible installation. The device is built into an aluminium extruded profile and rated to IP65 environmental protection, enabling operation in typical factory conditions.

Features and Benefits:


• 40mm beam resolution reduces detection gaps for small-object sensing
• 21m maximum scanning distance permits long-range safeguarding
• Type 4 safety classification achieves high-fidelity fault response
• 24V supply voltage supports standard industrial control systems
• SIL3 and PL e compliance ensures stringent functional safety

Applications


• Suitable for machine guarding in production lines
• Used with safety relays for access control systems
• Ideal for automated palletising protection zones
• Can be used for long-range perimeter safeguarding
• Used for integration in safety control architectures

What electrical supply tolerance is required?


The unit accepts 24V DC with an operational range of 19.2V to 28.8V and tolerates residual ripple up to 10%.

How is the device protected against environmental factors?


The housing provides IP65 ingress protection and can operate between 0°C and +55°C with non-condensing humidity.

What safety outputs and fault behaviour are provided?


In a fault at least one OSSD transitions to the OFF state and the system supports dual-channel output integration to disable hazardous states.

What mechanical and connector options exist for mounting?


The sender is supplied in an aluminium extruded profile with a DIN-style plug option and sliding-nut groove for side mounting.

How long is the expected mission time for safety calculations?


The specified mission time for safety assessment is 20 years.