Endress+Hauser FMX11 Series Hydrostatic Level Sensor Level Sensor

Subtotal (1 unit)*

₩831,040.00

Add to Basket
수량 선택 또는 입력
재고있음
  • 15 개 단위 배송 준비 완료
더 자세한 내용이 필요하신가요? 필요한 수량을 입력하고 '배송일 확인'을 클릭하면 더 많은 재고 및 배송 세부정보를 확인하실 수 있습니다.
수량
한팩당
1 +₩831,040.00

* 참고 가격: 실제 구매가격과 다를 수 있습니다

RS 제품 번호:
267-9269
Distrelec 제품 번호:
303-84-369
제조사 부품 번호:
FMX11-CA11DS06
제조업체:
Endress+Hauser
제품 정보를 선택해 유사 제품을 찾기
모두 선택

브랜드

Endress+Hauser

Product Type

Level Sensor

Device Type

Hydrostatic Level Sensor

Cable Length

6m

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

70°C

Maximum DC Voltage

28V dc

Standards/Approvals

CE mark

Series

FMX11

Hazardous Area Certification

No

COO (Country of Origin):
DE

Endress+Hauser FMX11 Series Level Sensor, 70°C Maximum Operating Temperature, 316L Stainless Steel Housing - FMX11-CA11DS06


This level sensor is a hydrostatic device designed to measure liquid levels in industrial environments. It uses a robust housing and a secure clamp mount to provide continuous level detection where a compact, fixed installation is required.

Features and Benefits:


• 316L stainless steel housing resists corrosion for longevity
• Hydrostatic sensing delivers continuous level measurement accuracy
• 6m cable enables flexible positioning and remote connection
• EPDM gasket ensures chemical resilience at sealing interfaces
• Operates from -10°C to 70°C for varied temperature conditions
• 28V DC supply with 22 mA current draw minimises power consumption

Applications


• Suitable for monitoring tank liquid height in processing plants
• Ideal for level control in storage vessels with clamp interfaces
• Used for fluid inventory measurement in chemical handling systems
• Can be used for continuous monitoring in water treatment sites

What mounting method does the device require?


It uses a clamp-style mount to attach securely to compatible fittings for fixed installations.

What materials contact process media?


The sensor housing is manufactured from 316L stainless steel with an EPDM gasket at sealing points.

How is electrical power supplied and consumed?


It operates from a DC supply up to 28V and typically draws 22 mA during normal operation.

What temperature range can it withstand during operation?


The unit functions across a minimum of -10°C up to a maximum of 70°C for standard applications.

Does it meet international conformity marks?


It carries the CE mark indicating compliance with applicable European directives.